Laserfiche WebLink
Shallow Tests <br /> TEST HOLE PERCOLATION RATE <br /> 1 (Parcel 1) 50 Min/In <br /> 2 (Parcel 2) 27.7 Min/In <br /> 3 (Parcel 3) 41.6 Min/In <br /> 4 (Parcel 4) 34.71 Min/In <br /> *See Results in Appendix. <br /> 6.7 Discussion of any protentional problems predicted and/or the need for an engineered or <br /> alternative septic system. In this area, the soils are classified as Redding Gravelly Loam and <br /> San Joaquin Sandy Loam. Due to this classification, percolation rate, and depth to ground water, <br /> a standard septic system similar to those found on the surrounding parcels would be recommended. <br /> 6.8 Discussion of percolation rates in relation to the type, size and location of future leach <br /> fields needed at the site. Based on the results of the percolation rates and the soils profiles, it is <br /> Dillon & Murphy's opinion that the subject parcels are suited for a typical on-site sewage disposal <br /> system. These systems should be properly designed and installed according to the current San <br /> Joaquin County criteria for standard septic systems. <br /> Based on the depth to groundwater in the area, and the size of the proposed parcel, it is our opinion <br /> on that the installation of any new proposed septic system, if property installed, should not <br /> adversely affect the quality of groundwater in the area. <br /> 7.0 CONCLUSION SECTION <br /> The conclusions of this report are based on the information provided regarding the proposed <br /> development, the use of the subject property, and the site conditions as they existed at the time we <br /> excavated our test hole and performed the percolation test. It was assumed that the test hole and <br /> percolation test results are representative of the subsurface conditions in the general area. <br /> Our services were performed, our findings obtained, and our conclusions proposed in accordance <br /> with generally accepted engineering principles and practices. The warranty is in lieu of all other <br /> warranties either expressed or implied. Test findings and statements of professional opinion do <br /> not constitute a guarantee or warranty, expressed or implied. <br /> Qp,OFESsj�� <br /> /ego 0 M UR,6 <br />■' ID <br /> U m <br /> ;rn <br /> 0.4e Mu h <br /> EXP.d g �* C.E. 45 77 <br /> C 1 V 1 <br /> F OF C Ali 4 <br />