My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HUNTER
>
642
>
2300 - Underground Storage Tank Program
>
PR0231148
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2026 3:36:55 PM
Creation date
7/1/2026 1:38:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231148
PE
2361 - UST FACILITY
FACILITY_ID
FA0000799
FACILITY_NAME
PARK ST PETROLEUM INC
STREET_NUMBER
642
Direction
N
STREET_NAME
HUNTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13906035
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
642 N HUNTER ST STOCKTON 95202
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of CP22 - UST FULL violations that have not been <br /> addressed for PARK ST PETROLEUM INC as of February 24, 2026. <br /> Open violations from May 27, 2025 inspection <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> 0 Supporting documents included <br /> Describe actions taken or will be taken to correct violation: RESULTS SENT 7/29/24-SJC Weblink Verification attached. <br /> ease remove this trom the violation <br /> Violation#30-2060015-Leak detection equipment located so leak is detected at the earliest possible <br /> opportunity(TCR 9d). <br /> OBSERVATION: The following sensors were not located to detect a leak at the earliest opportunity: <br /> - The 87 unleaded STP sump sensor was raised approximately 12 inches off the lowest point of the sump with <br /> approximately 20 gallons of liquid inside the sump. <br /> - The#9/10 UDC 001 sensor was raised approximately 8 inches off the lowest point of the under dispenser container <br /> with 1 approximately gallon of liquid. <br /> REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br /> possible opportunity. <br /> CORRECTIVE ACTION:The sensor was relocated to the lowest point of the sump by the service technician. Ensure <br /> that all monitoring equipment is maintained and located to detect a leak at the earliest opportunity. <br /> C11 This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: Corrected on site at time of inspection <br /> Violation#53-2010007-Submitted/maintained current Cert of Financial Responsibility/mech of financial <br /> assurance(TCR 11). <br /> OBSERVATION: Current financial responsibility documents were not found on site. <br /> REGULATION GUIDANCE:A copy of current financial responsibility documents are required to be maintained on site. <br /> CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br /> copy on site. <br /> Page 3 of 6 <br />