My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0041601
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHRISMAN
>
24427
>
2900 - Site Mitigation Program
>
WP0041601
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2026 2:05:12 PM
Creation date
7/17/2026 1:57:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
WP0041601
PE
2905 - SOIL BORING / PROBE - SITE MITIGATION
STREET_NUMBER
24427
Direction
S
STREET_NAME
CHRISMAN
STREET_TYPE
RD
City
TRACY
Zip
94378-
APN
25016011
CURRENT_STATUS
Active
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
24427 S CHRISMAN RD TRACY 94378-
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Safety and Health Plan <br /> Premium California Orchards Tracy, California Irerracon <br /> January 8, 2021 Terracon Project No. NA207103 <br /> Photoionization Detector <br /> Task Leader(s) will be knowledgeable in the operation of the photoionization detector. A manual <br /> on the operation of the PID and the appropriate calibration kit will be mobilized to the project site <br /> with the instrument. Photoionization detectors will be calibrated under field conditions each day <br /> prior to use. Task Leaders are instructed to consult the manufacturer's specifications for <br /> appropriate calibration gas and calibration techniques. <br /> A photoionization detector (PID) will be used to determine approximate hydrocarbon vapor <br /> concentrations in the BREATHING ZONE of site personnel. Continuous breathing zone air <br /> monitoring will be conducted during initial phases of intrusive activities (i.e., boring, excavation). <br /> If PID readings are less than 10 ppm, monitoring may be conducted at intervals of 10 minutes. If <br /> initial PID readings exceed 10 ppm, or if hydrocarbon odors become evident upon during auger <br /> advancement, continuous breathing zone air monitoring will be conducted. <br /> If sustained PID readings in the breathing zone exceed 25 ppm, personnel will upgrade to <br /> respiratory protection as outlined below. Personnel will remain in air purifying respirators until the <br /> photoionization detector readings in the breathing zone have fallen and stabilized below 25 ppm. <br /> 13.1 Site Action Levels <br /> Level D/D Modified Level C Site Evacuation <br /> < 25 ppm > 25 ppm > 300 ppm <br /> The Action Levels indicated above are for air in the breathing zone and NOT applicable to vapor <br /> above containerized soil samples. The Action Levels are established to prevent exposure to <br /> airborne petroleum hydrocarbon vapors in excess of established exposure limits. Although the <br /> Action Levels indicated for Site Evacuation are within the protective capacity of the respirator <br /> cartridges specified below, personnel will evacuate to the UPWIND side of the site if the <br /> continuous breathing zone vapor concentrations exceed these limits. The SSO will contact the <br /> Corporate Safety and Health Manager for discussion and re-evaluation of personal protective <br /> equipment and air monitoring requirements if airborne contamination exceeds Site Evacuation <br /> Action Levels. In the event that site evacuation is required, a modification of this safety and health <br /> plan will be issued with contingencies for combustible gas monitoring and upgrading to Level B <br /> personal protective equipment. <br /> 14.0 PERSONAL PROTECTIVE EQUIPMENT REQUIREMENTS <br /> The air monitoring regimen identified above will allow initial project activity to begin in LEVEL D <br /> personal protective equipment to include: <br /> 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.