Laserfiche WebLink
.......................................................................................................................................................................... <br /> STORAGE/TRANSPORT OF IDW* ❑ Describe site-specific procedures above for spill containment,container handling,as applicable. <br /> Spill/Release Risk: ❑ For liquids,provide secondary containment during storage. <br /> ❑Risk of incidental spill/release ❑Segregate incompatible chemicals during storage. <br /> ❑Risk of emergency spill/release ❑ Locate emergency gear(eyewash,fire extinguisher,spill kit,safety signage)near storage area,as applicable. <br /> ❑ For incidental spills;spill kit on-site for low-hazard releases(low-flammability/toxicity/quantity/volatility) <br /> *Investigation-Derived Waste ❑ For emergency spills:describe spill/release hazard and response plan/procedure above,and indicate <br /> Emergency response contact in Part B,"Emergency Response and First Aid." <br /> ❑ DOT/TDG/IATA-Regulated transport:see D.17."Hazmat/Dangerous Goods Shipp!ng/Tra nsportation." <br /> Geosyntec Procedures: HS-406-Unknown Hazardous Waste Drum Handling <br /> OFF-SITE MIGRATION OF AIRBORNE 1 ❑ Implement controls to minimize hazard migration(dust suppression,covers,foam,etc.). <br /> CONTAMINANTS ❑Community/perimeter air monitoring to be conducted per perimeter air monitoring plan;see E.3"Fence <br /> Line/Perimeter Air Monitoring." <br /> D.16. RADIATION HAZARDS(Other than Sunlight) ❑ Applicable ® Not Applicable, Not Anticipated <br /> Site-Specific Notes&Clarifications: <br /> E] RADIATION <br /> Potential hazard sources may include nuclear density gauges,host-facility X-ray equipment,radioactive contaminants(a,R,y), <br /> RADIATION medical or laboratory waste. Describe hazards&safety measures above in Site-Specific Notes&Clarifications. Conduct exposure <br /> monitoring,as appropriate;see Part E,"Air Monitoring,Worker Exposure Monitoring." <br /> Geosyntec Procedures: HS-126-Radiation Safety Program,HS-128-Ionizing and Non-Ionizing Radiation <br /> NON-IONIZING Potential hazard sources may include lasers,UV/IR sources,microwaves&high-frequency radio waves from cell-phone transmitter, <br /> RADIATION high-intensity visible light. Describe hazards&safety measures above in Site-Specific Notes&Clarifications. Conduct exposure <br /> monitoring,as appropriate;see Part E,"Air Monitoring,Worker Exposure Monitoring." <br /> Geosyntec Procedures: HS-128-Ionizing and Non-ionizing Radiation <br /> D.17. HAZMAT/DANGEROUS GOODS SHIPPING/TRANSPORTATION ❑Applicable ® Not Applicable, Not Anticipated <br /> MODE(S)OF TRANSPORT: ❑Road ❑ Rail El Air ❑Sea ❑ Inland Waterway ❑ International <br /> IMPORTANT:Ensure that each individual who will be involved in shipping/transportation of hazardous material is current with required training(awareness,function- <br /> specific,safety,security)in accordance with applicable regulatory authority(DOT,FAA,IATA,TDG),and ensure adherence to applicable regulations. <br /> Geosyntec Procedures: HS-135-Hazardous Materials Procedures <br /> Site-Specific Notes&Clarifications: <br /> PART E-AIR MONITORING, WORKER EXPOSURE MONITORING <br /> E.1. AIR MONITORING ❑ Applicable ® Not Applicable, Not Anticipated <br /> Site-Specific Notes,Clarifications: <br /> AIR-TESTING PARAMETERS-Select site-specific testing parameters;list associated equipment in Part C.2,Safety Equipment List. <br /> ❑VOCs ❑Oxygen(02)—oxygen meter ❑Particulates total dust meter <br /> ❑Photoionization detector(PID): X eV ❑Lower Explosive Level(LEL)-LEL meter El%Methane—methane meter <br /> El Flame ionization detector(FID) ❑Hydrogen sulfide(H2S)—H2S detector ❑Calibration kit for each parameter <br /> ❑Colorimetric indicator tubes—describe above ❑Carbon monoxide(CO)—CO detector ❑Other: <br /> SUBSTANCE-SPECIFIC(PRE-SET)ACTION LEVELS-Sustained breathing zone action levels(sustained general work-area levels for LEL). <br /> 19.5-23% Acceptable to continue work without 02 focused respiratory protection. <br /> O .......................................................................................:...................................................................................................................................................................................................................................................................................................................................................................................... <br /> ❑ z <19.5% STOP WORK,ventilate to raise 02 to>19.5%for re-entry. For persistent hazard,contact Corp.H&S Dept. <br /> (Oxygen) i.......................................................................................:.............. <br /> >23.0% STOP WORK,ventilate to lower 02 to<23%for re-entry. For persistent hazard,contact Corp.H&S Dept. <br /> IMPORTANT: Confirm sufficient oxygen is present(min.8-12%)to ensure accurate LEL readings. <br /> LEL(Lower <10%LEL Acceptable to continue working in work area;continue to monitor LEL. <br /> Explosive Limit) 1 STOP WORK. Implement controls(reposition workers,ventilate,contain/eliminate source,etc.);resume <br /> >10%LEL work ONLY when LEL readings are<10%,sustained. <br /> <1 ppm Acceptable to continue work without H2S-focused respiratory protection. <br /> t.......................................................................................:...................................................................................................................................................................................................................................................................................................................................................................................... <br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> H25 1-10 ppm exposures to<1ppm,or use APR*with VOC/acid-gas cartridges(yellow);do not exceed MUC*for respirator <br /> ❑ i....................................................................................... <br /> type;confirm acceptability of respirator usage with Corp.H&S Dept.(Hydrogen Sulfide <br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> >10 ppm exposures to<10ppm(with respirator),or<lppm(without respirator). For persistent levels>10 ppm,STOP <br /> WORK,contact Corp.H&S Dept. <br /> <25 ppm Acceptable to continue work without CO-focused respiratory protection. <br /> CO :..................................____ _ __________..............;...................................................................................................................................................................................................................................................................................................................................................................................... <br /> ❑ (Carbon Monoxide) >25 ppm Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> exposures to<25ppm. For persistent levels>25ppm,STOP WORK,contact Corp.H&S Dept. <br /> Geosyntec c T sk Name: <br /> HA Date: <br /> Page 12 <br /> consultants <br />