My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR2602100
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN CENTER SM
>
374
>
2900 - Site Mitigation Program
>
SR2602100
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2026 3:01:52 PM
Creation date
7/17/2026 2:56:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
SR2602100
PE
2900 - Site Mitigation Program
STREET_NUMBER
374
Direction
W
STREET_NAME
LINCOLN CENTER SM
City
STOCKTON
Zip
95207
APN
09741043
CURRENT_STATUS
In Review
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
374 W LINCOLN CENTER SM STOCKTON 95207
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
324
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<150 In this Air Quality Index(AQI)range,it's acceptable to continue work without respiratory protection. <br /> WILDFIRESMOKE ....—..................................................<...................................................................................................................................................................................................................................................................................................................................................................................... <br /> ❑ 151-500 Voluntary use of N95 respirator is appropriate. <br /> A 1forPM2.5 <br /> >500 STOP WORK,or use APR*with approval of Corp.H&S Dept. <br /> ❑ <OTHER> i.......................................................................................i...................................................................................................................................................................................................................................................................................................................................................................................... <br /> SITE-DERIVED ACTION LEVELS—Sustained breathing zone action levels;derived based on site contaminants;REVIEW WITH CORP.H&S DEPT.REQUIRED. <br /> <X ppm Acceptable to continue work without VOC-focused respiratory protection. <br /> ................................................................................................................................................................................................................................................................................................................................................................................................................. <br /> VOCs > ppm Implement controls(reposition workers,ventilation,containment,eliminate source,etc.) to lower VOC <br /> exposures to less than specified action level,or use APR*with approval of Corp.H&S Dept. <br /> ❑ V I it r ni i.......................................................................................<.............................................................................................................( oat eO ga c <br /> .......................................................................................................................................... <br /> Compounds) X to X ppm Use APR*with VOC cartridges(yellow or black);do not exceed MUC**for respirator type;confirm <br /> procedures for respirator usage with Corp.H&S Dept. <br /> >X ppm STOP WORK. Implement controls,for persistent levels greater than action contact Corp H&S Dept. <br /> <X mg/m3 Acceptable to continue work without particulate-focused respiratory protection. <br /> I.......................................................................................:...................................................................................................................................................................................................................................................................................................................................................................................... <br /> > m m3 Implement controls(water spray,reposition workers,ventilation,containment,etc.)to lower dust levels to <br /> g/ <br /> less than specified action level royal of Corp.AIRBORNE DUST i.......................................................................................:...................................._P...............................................................r.or use APR with apP H&5 Det.P............................_p................................................................................................................... <br /> ❑ (Total Particulates) X to X mg/m3 Use APR*with particulate cartridges appropriate for the hazard;do not exceed MUC**for respirator type; <br /> confirm procedures for respirator usage with Corp.H&S Dept. <br /> >mg/m3 STOP WORK. Implement controls. For persistent levels greater than action level,contact Corp H&S Dept. <br /> ❑ <OTHER> i.......................................................................................i...................................................................................................................................................................................................................................................................................................................................................................................... <br /> *Air-purifying respirator ** Maximum use concentration <br /> ................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................. <br /> Geosyntec Procedures: HS-111-Air Monitorinq,HS-602-Lead HS-605-Hydrogen Sulfide Wildfire Smoke THA Addendum <br /> E.2. OTHER WORKER EXPOSURE MONITORING 1 SAMPLING ❑ Applicable ® Not Applicable, Not Anticipated <br /> ❑ Heat/Cold Stress Testing/Monitoring ❑Wildfire Smoke—Tracking AQI(Air Quality Index) ❑<Other> <br /> ❑Air Sampling(sample collection,passive dosimeter) ❑ Ionizing or Non-ionizing Radiation Testing ❑<Other> <br /> ❑Wipe/Bulk Sampling(to evaluate worker exposure) ❑ Noise Testing <br /> Site-Specific Notes,Clarifications: <br /> Geosyntec Procedures: HS-109-Hearing Protection,HS-111-Air Monitorinq,HS-124-Heat Stress Prevention,HS-125-Cold Stress Prevention <br /> HS-126-Radiation Safety Program,HS-128-Ionizing and Non-ionizing Radiation,HS-601-Asbestos <br /> HS-602-Lead,HS-604-Respirable Crystalline Silica,HS-605-Hydrogen Sulfide <br /> E.3. FENCELINE 1 PERIMETER AIR MONITORING ❑ Applicable ® Not Applicable, Not Anticipated <br /> Fence line/perimeter air monitoring to be conducted in accordance with a separate"Perimeter Air Monitoring Plan"for this work;results from fence line/perimeter air <br /> monitoring shall NOT be used as the sole basis for determining work zone atmospheric hazards. <br /> Site-Specific Notes,Clarifications: <br /> PART F-APPROVALS, ACKNOWLEDGEMENTS <br /> F.1. THA PREPARATION, REVIEW/APPROVAL SIGNATURES A THA is typically prepared by project staff, often with input from an HSC, with <br /> review/approval, at a minimum, by PM or PD. Corporate H&S staff must be consulted as required or otherwise deemed appropriate*. <br /> Printed Name Signature Date <br /> THA PREPARED <br /> BY: <br /> THA Printed Name Signature Date <br /> REVIEWED/ <br /> APPROVED BY: <br /> (Project Manager or <br /> Project Director,at a <br /> minimum) <br /> *At a minimum,Corp.H&S must review/approve the THA review when Geosyntec staff will encounter"high hazards/high risks,"or perform critical tasks,such as(but not limited to): <br /> Climb ladders to heights>10' Implement lockout/tagout controls Instrument monitoring for critical exposure risks <br /> Use a personal fall apparatus Enter a trench/excavation>5'deep Wear a respirator <br /> Self-perform tasks classified as construction labor Work near heavy equipment or crane Presence of"high-risk"contaminant(s) <br /> Geosyntec° THA Date:sk Name: Page 13 <br /> consultants <br />
The URL can be used to link to this page
Your browser does not support the video tag.