Laserfiche WebLink
EP 2 <br />Jose Nunez 02/22/2018 02/13/2018 <br />Recommendation #9 <br />CUPA Inspection, Initial Site Visit, and Incident Investigation <br />The Business Owner/Operator Identification form was not completed with all the accurate information. <br />Business answered "NO" in CERS for storing on site reportable quantities of hazardous materials. Also <br />the the facility answered "NO" for having CalARP regulated substances on site. Rhonda Rallios is no <br />longer working for this business, and she is listed as the environmental and secondary emergency <br />contact in CERS. These information are inaccurate. This information must be current and submitted as <br />part of the business plan. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ra.gov/, enter the correct or updated information, and submit to the EHD for approval. <br />Resolution <br />The Hazardous Materials Business Plan has been updated and submitted on 2/13/2018. The facility has <br />answered \"YES\" to having a CalARP regulated substance and for storing on site reportable quantities <br />of hazardous materials in CERS. <br />EP 2 <br />Jose Nunez 02/22/2018 02/13/2018 <br />Recommendation #10 <br />CUPA Inspection, Initial Site Visit, and Incident Investigation <br />Any material that meets or exceeds the reportable quantity shall be reported in the facility's business <br />plan Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.mlepa.ca.gov/, add the materials listed below to the hazardous material inventory, and submit <br />to the EHD for approval. 957 gallons of Quorum Yellow P, 235 gallons Lift III, 1,356 gallons of Liquid 90 , <br />500 gallons of Quorum Clear V, 159 gallons of Oxonia (Perasan A), 76 gallons of Questar LAC, 1,465 <br />pounds of Sterilex Ultra Step, 1,640 pounds of Sani Step, 55 gallons of Boost 3200, All the following <br />chemicals were found on site and have not been reported. 75 gallons of Defoamer FG, 1000 gallons of <br />APC Aqua Chlor, 55 gallons of Alpet D2, 75 gallons of 10023, 65 gallons of 7009, 55 gallons of General <br />Purpose Degreaser, 2, 700 gallons of Smart Wash Original, 55 gallons of Smart Wash Organic, 1,150 <br />pounds of Anhydrous Ammonia, 55 gallons of Used Oil, 55 gallons of Used Glycol, 55 gallons of Used <br />Oil contaminated with Ammonia, 165 gallons of Hydrochloric Acid, 110 gallons of Refrigeration Oil, 3000 <br />gallons of of TEK-PG Glycol, 770 gallons of Cryogenic Nitrogen, 220 gallons of Cryogenic Oxygen, 200 <br />pounds of Nitrous Oxide, 1,245 cubic feet of compressed Oxygen gas, 354 cubic feet of Acetylene <br />compress gas, 55 gallons of Organic Peroxide and 500 gallons of Propane. <br />Resolution <br />The Hazardous Materials Business Plan has been updated and submitted on 2/13/2018 to reflect the <br />chemicals observed during the 1/24/2018 CUPA inspection. The facility has answered \"YES\" to having <br />a CalARP regulated substance and for storing on site reportable quantities of hazardous materials in <br />CERS. <br />EP 2 <br />Jose Nunez 02/22/2018 02/13/2018 <br />Recommendation #11 <br />CUPA Inspection, Initial Site Visit, and Incident Investigation <br />A site map was not completed and submitted as part of the business plan. A site map shall contain a <br />north orientation, loading areas, internal roads, adjacent streets, storm and sewer drains, access and <br />exit points, emergency shutoffs, evacuation staging areas, hazardous material handling and storage <br />areas, and emergency response equipment. If a site map element is not applicable for your facility then <br />list it on the map and label as "NA". Immediately log into the California Environmental Reporting System <br />(CERS) at http://cers.ralepa.ca.gov/, upload the correct or updated information, and submit to the EHD <br />for approval. <br />Resolution <br />The Hazardous Materials Business Plan has been updated and submitted on 2/13/2018 including an <br />attached site map with all the necessary elements. <br />CP 2 <br />Jose Nunez 02/22/2018 02/13/2018 <br />Recommendation #12 <br />CUPA Inspection, Initial Site Visit, and Incident Investigation <br />The emergency response procedures were not submitted to CERS as part of the business plan . A <br />business plan shall include the following emergency response procedures for a release or threatened <br />release of hazardous materials, including, but not limited to, the following: - immediate notification of <br />local emergency personnel and the Environmental Health Department (EHD) - procedures for the <br />mitigation of a release or threatened release to minimize any potential harm or damage to persons, <br />property, or the environment - evacuation plans and procedures, including immediate notice, for the site <br />Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/, upload the correct or updated information, and submit to the EHD for <br />approval. <br />Resolution <br />The facility has developed an Emergency Action Plan and coordinated the response efforts with the local <br />fire department via written letter to the fire department which included a copy of the Emergency Action <br />Plan and the Facility Evacuation Map. Included in the 2/13/2018 HMBP submission was an Emergency <br />Action Plan and Site Map. <br />