My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STOCKTON
>
720
>
2800 - Aboveground Petroleum Storage Program
>
PR0528050
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2019 10:46:20 AM
Creation date
9/14/2018 2:34:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528050
PE
2832
FACILITY_ID
FA0014456
STREET_NUMBER
720
Direction
S
STREET_NAME
STOCKTON
STREET_TYPE
AVE
City
RIPON
Zip
95366
APN
25936028
CURRENT_STATUS
01
SITE_LOCATION
720 S STOCKTON AVE
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: mm.sigov.crg/ehd <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />NUCAL TRANSPORT SERVICES <br />Facility Phone: <br />209' 254-2200 <br />Date <br />March 04. 2016 <br />Facility Address: <br />720 S STOCKTON AVE. RIPON. CA 95366 <br />CERS ID: <br />10184685 <br />Inspection Contact: <br />Randy Joa Uin <br />Title: <br />Fleet Maintenance Manaoer <br />Phone: <br />•209 254-2226 <br />Inspection Type: <br />ROUTINE INSPECTION - O eratin Permit <br />Program: <br />12832-ASTFAC 10 K - <r=100 K GAL CUMULATIVE <br />Consent For: <br />Ins ectlon 0 Photos 0 Sam les <br />Consent Given By: <br />Rand Joa Uin, Fleet Maintenance Manager <br />CCR = Cal fora a Code of Regulations HSC = Health and Safety Code CFR - Code of Federal Regulatcns <br />V = Violation R =Repeat violation COS = Corrected on site auring inspec' <br />Aboveground Petroleum Storage Act <br />101 <br />HSC 25270.4.5(a) <br />Failed to prepare and implement a written SPCC Plan in accordance with CFR Part 112 <br />u V e R ❑ COS <br />e V e R cl COS <br />102 <br />HSC 25270.4.5(a) <br />Failed to properly close a lank that is considered permanently closed <br />103 <br />HSC 25270.6(a) <br />Failed to file Business Plan or annual facility tank statement if capacity is over 10,000 gallons <br />o V ❑ R in COS <br />104 <br />HSC 25270.6i,b) <br />Failed to submit APSA fees <br />_ V c R - COS <br />105 <br />HSC 25270.8 <br />Faded to report spills or releases of 42 gallons (one barrel, or more <br />u V u R _ COS <br />106 <br />CCR 25185(c)(3) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />❑ V R o COS <br />107 <br />HSC 25404(e)(4) <br />Faded to report program data electronically <br />r V R COS <br />Requirement to Prepare and Implement a SPCC Plan <br />201 CFR 11 2,3(d) Plan certification by a Professional Engineer (PE) missing or incomplete <br />202 CFR 112.3(,)(1) I Failed to maintain a copy of the Pian on site <br />■ V R COS <br />V R COS <br />Amendment of SPCC Plan by Owners or Operators <br />30' <br />CFR 112.5(a) <br />Failed to amend Plan as necessary <br />■ V c R e COS <br />302 <br />CFR 112.5(b) <br />Faded to review Plan once every five years and/or implement any resulting amendments <br />e V c R e COS <br />303 <br />CFR 112.5(c) <br />Failed to have a PE certify technical amendments <br />■ V u R u COS <br />General Requirements for SPCC Plans <br />601 <br />CFR 1127 <br />Plan that does not follow the sequence specified in this section lacks a cross-referencing section <br />❑ V ❑ R ❑ COS <br />602 <br />CFR 112.7 <br />Plan lacks approval of management to fully commit the necessary resources to implement the Plan <br />V - R - COS <br />603 <br />CFR 112.7(a)(2) <br />Plan failed to discuss equivalent environmental protection, if applicable <br />V - R - COS <br />604 <br />CFR 112.7(;a)(3) <br />No facility diagram or didn't show location and contents of containers. transfer stations, and pipes <br />■ V R - COS <br />605 <br />CFR 112.7(,)(3) <br />Plan failed to address facility layout operations discharge prevention methods and containers <br />V R e COS <br />606 <br />CFR 112.7(a)(4) <br />Plan failed to contain procedu,es for reporting a discharge <br />r. V R o COS <br />607 <br />CFR 112.7(a)(5) <br />Discharge procedures are not adequately addressed if the facility has no response plan <br />c V e R o COS <br />608 <br />CFR 112.7(b) <br />Plan failed to include a description of potential equipment failure or provide equivalence <br />e V e R COS <br />609 <br />CFR 112.7(c) <br />Failed to provide secondary containment, diversionary structures, or equipment to prevent discharge <br />e V e R ❑ COS <br />610 <br />CFR 112.7(d) <br />Full or partial PE certified Plan failed to explain impracticability <br />❑ V e R ❑ COS <br />611 <br />CFR 112.7(d)(1) <br />Full or partial PE certified Plan failed to include spill contingency if no response plan submitted <br />e V e R o COS <br />612 CFR 112.7(d)(2) No written commitment of manpower, equipment, and materials to control and remove oil discharge o V ❑ R o COS <br />613 CFR 112.7(e) Failed to conduct inspections or maintain records for 3 years ■ V o R � COS <br />Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.