My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 10:44:17 AM
Creation date
9/24/2018 10:40:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,83/18/2015 02:13PM 66163492?1 KERN CONSTRjjrI, r PAGE 25/27 <br />0EEL) <br />SWRCB, January 2002 MAR 18 2015 Page �- of <br />n Tixmz+U 'nTQDTi %T4Z D i-tiNTATNMTNT (TTTN'l TFCTl[N[t <br />Test Method Developed By: ❑ UDC Manufacturer x Industry S Engineer <br />i�rp,Tu �1�oQC�Te��R,iT <br />❑ Other (Spec) <br />Test Method Used: 0 Pressure 0 Vacuum x Hydrostatic <br />0 Other (Spec) <br />Test Equipment Used: Incon TS -STS <br />Equipment Resolution:.001" <br />UDC Manufacturer: <br />UDC #1/2 <br />UDC #3/4 <br />UDC #2-3 Satellite <br />UDC #1 Satellite <br />Bravo <br />Bravo <br />Environ <br />Environ <br />UDC Material: <br />FRP <br />FRP <br />Poly <br />Poly <br />UDC De the <br />30" <br />30" 1 <br />30" <br />30" <br />Height from UDC Bottom to Top <br />of Hi hest Piping Penetration: <br />12" <br />12" <br />10" <br />10" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />10" <br />10" <br />0" <br />0" <br />Condition of UDC prior to <br />testing: <br />Cie—an <br />Clean <br />Clean <br />Clean <br />Portion of UDC Tested' <br />_ <br />1/2 <br />1/2 <br />1/2 <br />1/2 <br />Does turbine shut down when <br />UDC sensor detects liquid (bothl <br />product and water V <br />X Yes ❑ No ❑ NA <br />X Yes 0 No ❑ NA <br />XYes ❑ No ❑ NA <br />X Yes O No ❑ NA <br />Turbine shutdown response time <br />3 sec <br />3 Sec. <br />3 sec. <br />3 sec. <br />Is system programmed for fail- <br />safe shutdown?' <br />X Yes ❑ No ❑ <br />NA <br />X Yes ❑ No ❑ <br />NA <br />X Yes 0 No ❑ <br />NA <br />X Yes ❑ No ❑ <br />NA <br />Was fail-safe verified to be <br />operational?* <br />X Yes ❑ No ❑ <br />NA <br />X Yes 0 No ❑ <br />NA <br />XYes ❑ No ❑ NA <br />XYes ❑ No ❑ NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15 min. <br />15 Min. <br />15 Min. <br />15 Min. <br />Test Start Time: <br />1:12 <br />1:12 <br />1:12 <br />1:12 <br />Initial Reading <br />7.686 <br />4.566 <br />6.052 <br />2.825 <br />Test End Time: <br />1:27 <br />1:27 <br />1:27 <br />1:27 <br />Final Reading RF): <br />7.687 <br />4.566 <br />6.031 <br />2.826 <br />Test Duration: <br />15 Min <br />15 Min. <br />15 Min. <br />15 Min. <br />Change in Reading -Ri : <br />0.001 <br />0.00 <br />0.021 <br />0.001 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />0.002 <br />0.002 <br />Test:Result: <br />X:Pass 0 Fail <br />X Pass 11 FAR <br />X Pass Q Fair .. <br />X;P#ss ❑Fad ;: <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ <br />NA <br />X Yes ❑ No DNA <br />XYes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />X Yes ❑ No DNA <br />X Yes 0 No ❑ NA <br />I <br />X Yes ❑ No ❑ NA <br />I <br />X Yes ❑ No ❑ NA <br />I <br />Comments — (include information on repairs made prior to testing. and recommended_follow-upforfailed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk (*) is "ATO" or "NA', the entire UDC must be tested. (See SWRCB LG -160) <br />Received Time Mar, 18. 2015 3:16PM No.8366 <br />
The URL can be used to link to this page
Your browser does not support the video tag.