My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2014 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2014 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 11:15:30 AM
Creation date
10/19/2018 3:11:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2014 - 2015
FileName_PostFix
2014 - 2015
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUL 2 8 2014 <br />S WRCB, January 2002 ENVIR0NM8P4'ECTH <br />R_ Tr1.T.RTCTi',R CONTATNMTNT STIMP'r)O.STTNG DEPARTnnl=ntr <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fi11.Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: U Sump Manufacturer U Industry Standard X Professional Engineer <br />❑ Other (Spec#5�) _ <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: TS -STS icon sump test system Equipment Resolution: <br />tilt Sump Jt M11.Sump 9 1111 Sump # Fill Sump 0 <br />Sump Diameter: <br />Sump Depth: <br />_ <br />Height from Tank Top to Top of <br />HihestPiping Penetration: <br />_ <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to <br />testing: <br />Portion of Sump Tested <br />Sump Material: <br />_ <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (R : <br />Test End Time: <br />-- <br />Final Reading (RF): <br />Test Duration: <br />15 min <br />15 min 15 min <br />15 min <br />Change in Reading (RF -RT): <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 .002 <br />.002 <br />Test Result: <br />U Pa;s ❑ Fail <br />a Pass O Fall ❑Pass ❑ Fall <br />--- <br />0 Pugs ❑ Fall <br />Is there a sensor in the sum 7 <br />_._ <br />❑ Yes ❑ No <br />O Yes ❑ No ❑ Yes D No <br />❑ Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />_ <br />❑ Yes D No ❑ NA <br />11 <br />❑ Yes 0 N ❑NA ❑ Yes ❑No DNA <br />❑ Yes 0 N ❑ NA <br />Was sensor removed for testin ? <br />UYes ONo [INA <br />❑Yes ❑No ONA DYes ONn ONA <br />OYes ❑No DNA <br />Was sensor properly replacedand <br />verified functional after testing? <br />nYes 0 N 0 N <br />❑Yes 0 N 0 N OYes UNo DNA <br />Dyes ONo ❑NA <br />Comments — (include information on repairs made prim, to testing, and recor)lnrended follon,-rip for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.