My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
139
>
2300 - Underground Storage Tank Program
>
PR0231039
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2021 10:52:34 PM
Creation date
11/2/2018 4:16:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231039
PE
2361
FACILITY_ID
FA0006437
FACILITY_NAME
CHEVRON STATION #90557*** (INACT)
STREET_NUMBER
139
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13730012
CURRENT_STATUS
02
SITE_LOCATION
139 S CENTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CENTER\139\PR0231039\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
2/29/2012 8:00:00 AM
QuestysRecordID
119913
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INITORING PROCEDURES SINGLE W- L PIPING <br /> b-JNTINUOUS ELECTRONIC MONITORIr./ SUMPS <br /> SINGLE WALL PIPING <br /> SUMP MONITOR: X LIQUID SENSOR Veeder-Root TLS-350 Single Float Series 794390-208 <br /> EQUIPMENT AT THIS FACILITY IS: Veeder-Root TLS-350 PLLD Series 848480-001 <br /> All single contained piping is continuously monitored electronically by a system that can sense a leak <br /> at of 3 gallons or more per hour at 10 lbs. per square inch of line pressure within 1 hour at more <br /> than one location with positive shut down. The line pressure monitor is capable of sensing a <br /> pressure loss in the system and disables the flow of product through the lines. All product lines are <br /> sloped down towards the tank, and if the pressure sensor is activated, any liquid in the product lines <br /> will flow backwards toward the sump area. There is a sensor in the sump area that detects any <br /> liquid present there. The system has both visible and audible alarms that are activated when there is <br /> liquid in the sump. At least annually, the system is capable of detecting a release from the primary <br /> piping equivalent to .1 gph defined at 150% operating pressure. <br /> RESPONSE PLAN <br /> If the system goes into the alarm mode, the Operator or his designate will check the alarm panel to <br /> verify that there is a leak condition and then silence the audible alarm. The Operator or his designee <br /> will immediately contact Chevron dispatch and advise them of the situation so that they can contact <br /> the appropriate personnel who will follow the instructions outlined in the "Leak Response Plan", <br /> which is part of your Hazardous Material Management Plan. All follow up will be completed within <br /> the month the problem occurred. <br /> The monitoring system will be inspected daily. The Operator or an employee appointed by the <br /> Operator will follow the same procedures as outlined for monitoring the double contained product <br /> tanks. <br /> PREVENTATIVE MAINTENANCE <br /> The monitoring equipment shall be inspected and certified annually. Maintenance will be performed <br /> annually or as needed. All work performed to the monitoring system will be in accordance to the <br /> manufacturers recommendations. <br /> TRAINING <br /> Tank operators are trained on the proper operations of the monitoring equipment per the <br /> manufacturer's instructions. <br /> CATHODIC PROTECTION: STEEL SWING JOINTS/FLEX CONNECTORS/TURBINES <br /> Sacrificial anode Cathodic protection system is installed adjacent to all product piping steel <br /> connections in contact with soil. The anodes force direct current through the soil to the metal <br /> surface, which overcomes the potential corrosive effects of the soil and creates a long-lasting, <br /> continuous protection from corrosion. The system is designed and engineered by NACE-certified <br /> corrosion experts. <br /> PREVENTATIVE MAINTENANCE <br /> The Cathodic protection system shall be inspected and certified annually. Maintenance will be <br /> performed annually or as needed. All work performed to the system will be in accordance to the <br /> manufacturers recommendations. <br /> Chevron Maintenance Dispatch (24 Hour) 1-800-423-3528 <br />