Laserfiche WebLink
E <br />1. PIPING SUMP TESTING <br />0 Page 3 of 4 <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: See attached testing procedures <br />Equipment Resolution: <br />Sump # 91 <br />Sump # <br />Sump # <br />Sump # <br />Sump Diameter: <br />48" <br />Sump Depth: <br />69" <br />Sump Material & Manufacturer: <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />12" <br />_ <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />24" <br />Condition of sump prior to testing: <br />Fair <br />Sump <br />Portion of Sum Tested' <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Above highest <br />penetration <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)? <br />❑ Yes ❑ No E NA <br />El Yes ❑ No E NA <br />❑Yes ❑ No ® NA <br />❑ Yes ❑ No ❑ NA <br />Turbine shutdown response time <br />Is system programmed for fail-safe <br />shutdown?* <br />E] Yes❑ No E]NA <br />❑Yes ❑ No ®NA <br />❑Yes ❑ No F]NA <br />❑Yes ❑ No Z NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes❑ No ❑ NA <br />[-]Yes [—]No ®NA <br />❑Yes ❑ No ❑ NA <br />❑Yes [:]No Z NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />10:28am <br />Initial Reading (Ri): <br />2.7806 <br />Test End Time: <br />10:43am <br />Final Reading (RF): <br />2.7796 <br />Test Duration: <br />15 mint <br />Change in Reading (RF -R,): <br />0.00100 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />0.002 <br />0.002 <br />Test Result: <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />El Pass ❑ Fail <br />❑ Pass ❑ Fair <br />Was sensor removed for testing'? <br />® Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />ZYes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See S)VRCB LG -160) <br />