My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1427
>
2300 - Underground Storage Tank Program
>
PR0521942
>
COMPLIANCE INFO 2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:31 AM
Creation date
11/2/2018 8:12:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0521942
PE
2371
FACILITY_ID
FA0014921
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
1427
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
16902016
CURRENT_STATUS
01
SITE_LOCATION
1427 S AIRPORT WAY
P_LOCATION
02
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\1427\PR0521942\COMPLIANCE INFO 2004-2007.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 3 of 7 <br /> 5. SECONDARY PITE T'ESTE%iG <br /> Test Method Developed By: 0 piping Manufacturer X Tndust 7 Standard 0 Professional Engineer <br /> o other(5pecrfy) <br /> Test Method.Used: X Pressure ❑Vacuum ❑Hydrostatic <br /> ❑other(Specrfy) <br /> Test Equipmcnt Used:Air Compressor and 0-15#dial gauge Equiprnent Resolution: <br /> Fiping Run#91 Vent Piping Run# Piping Run# Pipin€,Run# <br /> Piping Material: Fiberglass <br /> piping'Manuficturer: A.0.Smith <br /> Piping Diameter. TI <br /> Length of Piping Run: 20' <br /> Product Stared: Gasoline <br /> Method and location of Test boots at the end <br /> i ' -run isolatiow. of the pipe ran <br /> Wait time between applying <br /> pressure/vacuumlwater and 10 minutes <br /> s#xtin: test: <br /> Test Start Time: 2:15 pm <br /> Initial Reading(RT): 5 psi <br /> Tcst End Time: 2:45 pm <br /> Final Reading(Rv): 5 psi <br /> Test Duration.: 30 minutes <br /> Change in.Reading(Rv-R,): 0 Change <br /> Pass/Fail Threshold or 0 Chan c— ass <br /> Criteria: g _p <br /> Test Result: X Faso 0 Fail ❑ Pass 0 Fail ❑ Pass ❑Fail j i=l ??ass ❑Fail <br /> Comrnenta— (include inform ation on repairs made prior io testing. and recommena¢d follm,2E&rfailed tr-t <br />
The URL can be used to link to this page
Your browser does not support the video tag.