Laserfiche WebLink
S"CB,January 2002 Page_of <br /> G. SECONDARY PIPE_ TESTING <br /> Test Method Developed By: X Piping Manufacturer Industry Standard i-'Professional Engineer <br /> ❑Other(Sped) <br /> Test Method Used: X Pressure Vacuum ❑Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Pressure Gauges in Psi/Nitrogen Equipment Resolution: 1/10-15 Psi <br /> Piping Run#5 Piping Run# Piping Run# Piping Run# <br /> Piping Material: Fiberglass <br /> Piping Manufacturer: Ameron <br /> Piping Diameter: 4" <br /> Length of Piping Run: Approx.7' <br /> Product Stored: Jet A <br /> Method and location of Test boot at <br /> i in -run isolation: Return Sump#2 <br /> Wait time between applying 15 Minutes <br /> pressure and starting test: <br /> Test Start Time: 10:30 <br /> Initial Reading(Rl): 3 Psi <br /> Test End Time: 11:30 <br /> Final Reading(RF): 3 Psi <br /> Test Duration: 1 Hour <br /> Change in Reading(RF-Rj): 0 Psi <br /> Pass/Fail Threshold or No Loss in Psi <br /> Criteria: <br /> Test Result: X Pass ❑Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail [] Pass ❑ Fail <br /> Comments—(include information on repairs made prior to testing and recommended allow-up for failed tests) <br />