• <br />VENTILATE YOUR AREA <br />WEAR SAFETY PROTECTION <br />MANDATORY <br />MANDATORY <br />NO <br />0 <br />• ELECTRIC TOOLS <br />> IGNITION SOURCES <br />Ensure that the workspace is operating below <br />the LEL (lower explosive limit) before starting <br />work. Test regularly or monitor continuously <br />A Confined -space Certification is required <br />when installing this fitting inside Tank Sumps <br />STEP 1 BEFORE BEGINNING WORK ON YOUR JOBSITE. YOU MUST <br />EVALUATE THE EXISTING SUMPS, PIPE, CONDUIT AND <br />FLEXIBLE ENTRY BOOTS YOU WILL BE RETROFITTING_ <br />FOLLOW THESE STEPS; <br />A) Ensure the sump material is fiberglass only. <br />B) Ensure the piping is fiberglass, galvanized steel or PVC coated steel only. <br />C) If the PVC coated conduit is Ocal-Blue brand, you must strip the PVC away from the <br />fitting area and rough up the steel conduit beneath. <br />D) Ensure that the conduit has not rusted through. This fitting should not be bonded with any <br />adhesive to a corroded or partially corroded conduit line. You must replace the conduit. <br />WHEN READY, BEGIN WORK ON YOUR JOBSITE BY ENTERING ALL THE SUMPS YOU WILL <br />BE INSTALLING THE F -SERIES RETROFIT -S FITTING IN AND: <br />E) Remove or move any components that will obstruct your access to the sump wall. <br />F) Remove any fuel, oils, contaminants, water or debris. Dispose of HAZMAT per local codes. <br />G) Secure all conduit lines by bracketing them to at least one rigidly connected conduit or the <br />riser. Do not allow conduit endpoints to move or act as a lever. <br />STEP 2 <br />7 <br />COMPLETE ❑ <br />Before starting work, ensure all fuels <br />and flammables have been removed. <br />Test/monitor your LELss and ventilate. <br />Remove interior boot from the wall to <br />expose the fitting interior and bolts. <br />DO NOT USE TOOLS THAT <br />CAN DAMAGE THE PIPE. <br />Use a protractor or other measurement <br />tool to measure piping angles. <br />ii -F -Seri es -Retrofit -S -13B <br />' <br />Interior Bolts <br />El <br />3 s1. E k�•, ;. H <br />Now %WM woo-. <br />f <br />Interior Boot <br />7 <br />COMPLETE ❑ <br />Before starting work, ensure all fuels <br />and flammables have been removed. <br />Test/monitor your LELss and ventilate. <br />Remove interior boot from the wall to <br />expose the fitting interior and bolts. <br />DO NOT USE TOOLS THAT <br />CAN DAMAGE THE PIPE. <br />Use a protractor or other measurement <br />tool to measure piping angles. <br />ii -F -Seri es -Retrofit -S -13B <br />