My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:35:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
5/19/2017 9:21:29 PM
QuestysRecordID
3390491
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. Piping Sump Testing <br /> Test Method Developed By: ❑Tank Manufacturer ❑X Industry Standard ❑Professional Enqineer <br /> Test Method Used: ❑ Pressure <br /> ❑Vacuum Q Hydrostatic <br /> Test Equipment Used: Incon TS STS Leak Detector Equipment Resolution:±0.002 <br /> Sump# 87M Sump# 87S Sump# 91 Sump# <br /> Sump Diameter: 42" 42" <br /> 42" <br /> — --------- ----- --- <br /> - ----- -. ----- - <br /> - <br /> Sump Depth: 45" 43" � 42' _ <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 12" --- <br /> Highest Piping Penetration: 26" 12" <br /> Height from Tank Top to Lowest 23„ <br /> Electrical Penetration: 21" 21" <br /> Condition of sump prior to testing: OK OK OK <br /> OK <br /> Portion of Sump Tested 1s" 29" 16'.—, -- <br /> sump <br /> 5'sump sensor detects liquid(both O Yes O No ® NA O Yes O No ® NA O Yes O No ® NA O Yes O No ® NA <br /> roductand water 7' <br /> Turbine shutdown response time N/A NIA N/A N/A <br /> Is system programmed for fail-safe <br /> shutdown?' O Yes O No ® NA O Yes O No ® NA O Yes O No ® NA O Yes O No ® NA <br /> Was fail-safe verified to be <br /> operational?* O Yes O No ® NA O Yes O No ® NA O Yes O No ® NA O Yes O No ® NA <br /> Walt time: 15 min 15 min 15 min 15 min <br /> at Start Time: 10:38 10:06 <br /> _ 11:02 <br /> Initial Reading: —_-- 4.4537 2.5602 ---- — --- -- ------ <br /> 1.3109 <br /> Test End Time 10:53 10:21 11:17 <br /> Final Reading: 4.4537 2.5607 <br /> 1.3107 <br /> Test Duration(hh:mm): 00:15 00:16 00:15 00:00 <br /> Change in Reading: ----0.0000 0.0005 -0.0002 0.0000 <br /> Pass/Fail Threshold or Criteria: ±0.002 ±0.002 ±0.002 ±0,002 <br /> Test-ftosplt: 0 Pass O fail ®:Pass O Fail * Pass O Fail *Pass O Fail. <br /> Was sensor removed for testing? *Yes O No O NA *Yes O No O NA *Yes O No O NA ®Yes O No O NA <br /> Was sensor properly replaced and O Yes O No ® NA O Yes O No ® NA O Yes O No ® NA O Yes O No ® NA <br /> verified functional after testing? <br /> Comments: <br />