My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:35:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
5/19/2017 9:21:29 PM
QuestysRecordID
3390491
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. UDC Testing <br /> Test Method Developed By: ❑Tank Manufacturer ©Industry Standard ❑ Professional Enoineer <br /> Test Method Used: ❑Pressure ❑vacuum © Hvdrostatic <br /> Test Equipment Used: Incon TS STS Leak Detector Equipment Resolution:±0.002 <br /> UDC# 1-2 UDC# 3-4 UDC# 5-6 UDC# <br /> UDC Manufacturer: Bravo Bravo Bravo <br /> UDC Material: Steel Steel steel <br /> UDC Depth: 9 9 9 <br /> Height from UDC Bottom to 0 0 0 <br /> Top of Highest Piping - <br /> Penetration: <br /> Height from UDC Bottom to <br /> 0 g 0 <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to OK OK OK - OK <br /> testing: <br /> Portion of UDC Tested 100% 100% 100% 100% <br /> Does turbine shutdown when O Yes O No ® NA O Yes O No ® NAI O Yes O No ® NA O Yes O No ®NA <br /> UDC sensor detects liquid? <br /> Turbine shutdown response N/A N/A N/A N/A <br /> time: --- <br /> Is system programmed for fail- O Yes O No ® NA O Yes O No ®NA O Yes O No ® NA O Yes O No ® NA <br /> safe shutdown? <br /> Was fail-safe verified to be O Yes O No ® NA O Yes O No ® NA O Yes O No IS NA O Yes O No ® NA <br /> operational? <br /> Waft time: 15 min 15 min — 15 min ---- _ 16 min — <br /> Test Start Time: 11:02 11:21 -__ 12_14 <br /> Initial Reading: 2.1764 1.6741 1.5946 — <br /> Test End Time: 11:17 11:36 12:29. <br /> Final Reading: -- 2.1768 1.6743 1.5945 <br /> -Test Duration(hh:mm): 00:16 00:15 00:15 00:00 — <br /> Change in Reading: 0.0004 0.0002 -0.0001 <br /> Pass/Fail Threshold or ±0.002 ±0.002 ±0.002 ±0.002 <br /> Criteria: <br /> Test Result: ® Pass O Fail ® Pass O Fail * Pass O Fail ® Pass O Fail <br /> Was sensor removed for Q Yes O No ® NA O Yes O No ® NA O Yes O No ® NA O Yes O No ® NA <br /> testing? <br /> Was sensor properly replaced Q Yes O No ® NAI O Yes O No ® NA O Yes O No ® NA <br /> and verified functional after O Yes O No ® NA <br /> testing? -----1-------------�--- ----------- <br />