Page'3 of 14 i ESR-1917 <br /> accordance with ACI 318 Appendix D and this report must be installations into the soffit of concrete on steel deck <br /> modified by a factor of 0.60. assemblies, see Figure 5. <br /> 4.1.12 Structural Sand Lightweight Concrete over Metal 4.4 Special Inspection: <br /> Deck:Use of structural sand lightweight concrete is allowed Special inspection is required, in accordance with Section <br /> in accordance with values presented in Table 3 and 1704.13 of the IBC and Section 1701.5.2 of the UBC. The <br /> installation details as show in Figure 5. special inspector must be on the jobsite continuously during <br /> 4.2 Allowable Stress Design: anchor installation to verify anchor type,anchor dimensions, <br /> 4.2.1 General: Design resistances for use with allowable concrete type, concrete compressive strength, hole <br /> stress design load combinations calculated in accordance dimensions,hole cleaning procedures,anchor spacing,edge <br /> with Section 1605.3 of the IBC and Section 1612.3 of the distances, concrete thickness, anchor embedment, and <br /> UBC, must be established as follows: tightening torque. <br /> Rd 5.0 CONDITIONS OF USE <br /> R,nw,ASD= a (5) The Hilti KB-TZ anchors described in this report comply with <br /> the codes listed in Section 1.0 of this report, subject to the <br /> where R, R,represents the limiting design strength in <br /> following conditions: <br /> tension (¢Na)or shear(OV)ascalculated according to ACI 5.1 Anchor sizes, dimensions and minimum embedment <br /> 318 Sections D.4.1.1 and DA.1.2 and Section 4.1 of this depths are as set forth in this report. <br /> report.For load combinations including earthquake,the value 5.2 The anchors must be installed in accordance with the <br /> R,in Equation(5) must be multiplied by 0.75 in accordance manufacturers published instructions and this report.In <br /> with ACI 318 Section D.3.3.3. Limits on edge distance, case of conflict,this report governs. <br /> anchor spacing and member thickness,as given in Tables 3 <br /> and 4 of this report, must apply. Allowable service loads for 5.3 Anchors must be limited to use in cracked and <br /> single anchors in tension and shear with no edge distance or uncracked normal-weight concrete and structural sand <br /> spacing reduction are provided in Tables 6 through 9, for lightweight concrete having a specified compressive <br /> illustration.These values have been derived per Equation(5) strength, P,,of 2,500 psi to 8,500 psi(17.2 MPa to 58.6 <br /> using the appropriate strength reduction factors 0fromTables MPa), and cracked and uncracked normal-weight or <br /> 3 and 4 and the a factors provided in Section 4.2 of this structural sand lightweight concrete over metal deck <br /> report. having a minimum specified compressive strength, P,, <br /> The value of a must be taken as follows: of 3,000 psi(20.7 MPa). <br /> REFERENCE FOR STRENGTH a 5.4 The values of F.used for calculation purposes must not <br /> REDUCTION FACTORS Including Excluding exceed 8,000 psi (55.1 MPa). <br /> Seismic Seismic 5.5 Loads applied to the anchors must be adjusted in <br /> ACI 318 Section D.4.4 1.1 1.4 accordance with Section 1605.2 of the IBC and <br /> ACI 318 Section DA 5 1.2 1.55 Sections1612.2 or 1909.2 of the UBC for strength <br /> design, and in accordance with Section 1605.3 of the <br /> 4.2.2 Interaction:In lieu of ACI 318 D.7.1,D.7.2 and D.7.3, IBC and Section 1612.3 of the UBC for allowable stress <br /> interaction must be calculated as follows: design. <br /> For shear loads V:: 0.2 V,a„.,,.,the full allowable load in 5.6 Strength design values must be established in <br /> tension T.,,so may be taken. accordance with Section 4.1 of this report. <br /> For tension loads T, 0.2 T,b,.Aso, the full allowable load 5.7 Allowable design values are established in accordance <br /> in shear V,,,,,, ,so may be taken, with Section 4.2. <br /> For all other cases: 5.8 Anchor spacing and edge distance as well as minimum <br /> member thickness must comply with Tables 3 and 4. <br /> T V <br /> + < 1.2 (6) 5.9 Prior to installation, calculations and details <br /> Taibw,ASD V.1ADw,ASD demonstrating compliance with this report must be <br /> submitted to the code official. The calculations and <br /> details must be prepared by a registered design <br /> 4.3 Installation: professional where required by the statutes of the <br /> Installation parameters are provided in Table 1 and in Figure jurisdiction in which the project is to be constructed. <br /> 2. The Hilti KB-TZ must be installed according to 5.10 Sincean ICC-ES acceptance criteria for evaluating data <br /> manufacturer's published instructionsandthis report.Anchors to determine the performance of expansion anchors <br /> must be installed in holes drilled into the concrete using subjected to fatigue or shock loading is unavailable at <br /> carbide-tipped masonry drill bits complying with ANSI this time, the use of these anchors under such <br /> 6212.15-1994. The nominal drill bit diameter must be equal conditions is beyond the scope of this report. <br /> to that of the anchor. The drilled hole must exceed the depth <br /> of anchor embedment by at least one anchor diameter to 5.11 Anchors may be installed in regions of concrete where <br /> permit over-driving of anchors and to provide a dust collection cracking has occurred or where analysis indicates <br /> area as required. The anchor must be hammered into the cracking may occur(f,>f,), subject to the conditions of <br /> predrilled hole until at least four threads are below the fixture this report. <br /> surface. The nut must be tightened against the washer until 5.12 Anchors may.be usedto resist short-term loading due-to <br /> the torque values specified in Table 1 are achieved. For wind or seismic forces,subject to the conditions of this <br /> installation in the soffit of concrete on steel deck assemblies, report. <br /> the hole diameter in the steel deck not exceed the diameter <br /> of the hole in the concrete by more than'/,inch(32 mm).For 5.13 Where not otherwise prohibited in the code, KB-TZ <br /> member thickness and edge distance restrictions for anchors are permitted for use with fire-resistance-rated <br />