Laserfiche WebLink
_ _ <br /> 4• <br /> 8.3.11.Apply the first clip at a distance from the dead end of 8.4. DEADMEN <br /> the wire rope that is equal to the largest width of the clip used. 8,4,1.A deadman is typically a reinforced concrete beam and <br /> See FIGURE 8-5. <br /> should be designed according to the applicable American <br /> Concrete Institute code. <br /> 15tcup 3id clip 2"d clip 8.4.2.The length of a deadman is typically equal to the length <br /> Live End Thimble of the tank. <br /> 8.4.3. Deadmen may be installed in multiple sections as long <br /> as the total length of the assembled deadman is appropriate <br /> for the Installed tank, and as long as each section contains at <br /> Loop <br /> Head End least two balanced anchor points. <br /> 8.4.4.The width and thickness of a deadman depends on the <br /> FIGURE 8-5 tank diameter,water-table height,number of containment <br /> 8.3.12 For each clip, apply a U-bolt over the dead end of the sumps and burial depth. <br /> wire rope.See FIGURE 8-5. G <br /> 8.4.5.See TABLES-4 for typical deadmen dimensions for. <br /> NOTE: Live end rests in the saddle. Xerxes tanks(other than 10-foot-diameter tanks with a capac- <br /> 8.3.13.When only 2 clips are required, apply the second clip ity greater than 25,000 gallons), given the following scenario: _ <br /> as close to the loo or thimble as possible.See FIGURE 8-5. an empty tank,a 3-foot burial depth,groundwater to grade, <br /> p <br /> and one containment sump. <br /> 8.3.14.When more than 2 clips are required,apply the second <br /> clip as close to the loop or thimble as possible,turn nuts on the Typical <br /> second clip firmly, but do not tighten initially.See FIGURE 8-5. Tank Diameter Deadman Dimensions <br /> (Width x Depth) <br /> 8.3.15.When more than 2 clips are required,space additional <br /> clips equally between the first 2,take up rope slack and 61 12"x 12" <br /> tighten nuts on each U-bolt evenly. $' 12"x 12" <br /> 8.3.16.Tighten all hardware uniformly and follow the manufac- 10' 18„x 9" <br /> turer's torque specifications. Double-check the tightness once <br /> the anchoring system is complete. 12' 36"x 8" <br /> 8.3.17.If forming a loop in the wire rope,a splice is required <br /> for connecting the two ends together. TABLE 8-4 <br /> 8.3.17.1.Standard rigging practice for splicing wire rope calls 8A.5.1.If tanks are installed with any conditions different from <br /> for using twice the number of clips recommended for a single- <br /> end termination. those identified In POINT 8.4.5,and/or if tanks are 10-foot- <br /> diameter tanks with a capacity greater than 25,000 gallons, <br /> 8.3.17.2. Use a minimum of 4 clips for a 3/8-inch wire rope the installation may require either a deeper burial or deadmen <br /> and a minimum of 6 clips for a 1/2-inch wire rope. larger than those shown in TABLE 8-4. Contact technical sup- <br /> 8.3.17.3. Place the rope ends parallel to each other and install <br /> port at Xerxes Minneapolis,MN,for further information. k' <br /> the clips as shown in FIGURE 8-6. 8.4.6.Lay the deadmen in the excavation parallel to the tank <br /> and outside of the tank"shadow."See FIGURE 7-2. <br /> 318"Wire Rope 8.4.7. In installations where two or more tanks are installed <br /> 4( Live End ) —Dead End using deadmen: <br /> Load 8.4.7.1.a separate anchor point must be provided for each <br /> anchor strap <br /> Load <br /> 8.4.7.2,the minimum spacing between the tanks must be <br /> Dead End Live End ),I equal to or greater than the width of the deadman used for the <br /> tanks <br /> 112"Wire Rope <br /> 8.4.7.3.each tank will have its own set of deadmen, however, <br /> t Uve Enddead End one deadman may be used between two tanks if the deadman <br /> -*--Load c i is double the width of the single deadman specified for tanks <br /> ra <br /> Load in SECTION 7. a <br /> Dead End Live End 8.5. XERXES PREFABRICATED DEADMEN <br /> 8.5.1.Xerxes-supplied prefabricated deadmen are pre-engi- <br /> neered and sized to the tank ordered.As with any deadmen, i <br /> FIGURE 8-6 water-table height,number of containment sumps and burial <br /> depth must be considered. <br /> 16 <br />