My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LODI
>
2500
>
2300 - Underground Storage Tank Program
>
PR0231356
>
INSTALL_1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2022 11:42:14 AM
Creation date
11/5/2018 5:52:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1997
RECORD_ID
PR0231356
PE
2361
FACILITY_ID
FA0003815
FACILITY_NAME
TESORO (MOBIL) 68154
STREET_NUMBER
2500
Direction
W
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
02740006
CURRENT_STATUS
01
SITE_LOCATION
2500 W LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LODI\2500\PR0231356\1997 INSTALL .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Tank Sumps <br />Tank Sumps are used at the <br />beginning of the GBOFfex Piping <br />System. Installed on the top of the <br />tank, they provide surface access to <br />a tank's pump, fittings and other <br />Piping connections. They also serve <br />as a means of secondary <br />containment and leak collection. <br />• <br />4 <br />.e <br />r, <br />(A. <br />}Fye <br />In-line Piping Sumps <br />In -Line Piping Sumps are used for <br />long piping runs which require the <br />connection of two pipe sections. <br />This sump provides surface access <br />and secondary containment for <br />these plumbing connections. May <br />also be used to contain other piping <br />components. <br />Stabilizer Bar Assemblies <br />Required for all Standard <br />Dispenser Sumps. Includes: <br />stabilizer bar with fasteners, spacer <br />Plate and valve plate with <br />fasteners, Accommodates boss <br />mounted shear valves only. <br />Stabilizer Bars must be installed prior <br />to backlilling or pouring concrete. <br />Flexible Entry Boots <br />These rubber compression type <br />boots are installed Into the wall of <br />containment sumps to seal all pipe <br />and conduit entries. The 1-1/2' <br />(FEB -8150) entry boot Is used for <br />all 1-1/2" GeoFlex Pipe entries. A <br />variety of sizes are available to seal <br />rigid pipe and conduit. <br />Junction Tees <br />A brass fitting installed in junction <br />type Dispenser Sumps. Typically <br />used in pressure piping systems <br />which are routed in series. This tee <br />has two threaded openings for <br />coupling connections and one <br />threaded opening for riser pipe <br />connections. <br />Shallow Dispenser Sumps <br />Shallow containers for under <br />dispenser containment. Recom- <br />mended for all suction type piping <br />systems and pressure piping <br />systems using the Liquid Interstitial <br />Monitoring System. They provide <br />convenient access to, and <br />secondary containment of, the pipe <br />connections. <br />14 <br />GeoFlex Piping <br />A flexible underground piping used <br />for use transmission of flammable <br />and other types of hazardous <br />liquids in both pressure and suction <br />type systems. Both GeoFlex 18 11 <br />are available In 1-1/2' and 2' pipe <br />sizes packaged in either canons or <br />reels. <br />Terminating Elbows <br />A brass fitting installed in <br />terminating type Dispenser Sumps. <br />Used in both pressure and suction <br />piping systems, this elbow fitting <br />has one threaded opening for <br />coupling connections and one <br />threaded opening for riser pipe <br />connections. <br />Deep Dispenser Sumps <br />Deep containers for under <br />dispenser containment. Used <br />primarily for pressure piping <br />systems which are routed in series <br />and require piping fall to one or <br />more containment sumps. They <br />Provide convenient access to, and <br />secondary containment of, the pipe <br />connections. <br />Pipe <br />these brass couplings are <br />designed specifically for GeoFlex <br />Piping. They are Infernally <br />expanded to the ends of the <br />flexible pipe section using the <br />Environ Coupling Machine. Each <br />coupling assembly includes a brass <br />Insert, swivel and ferrule. <br />Product Offsets <br />Used with some model dispensers <br />which require pipe entry locations <br />significantly off center. The offset <br />fitting permits the use of standard <br />dispenser sumps to accommodate <br />these applications. Refer to the <br />Dispenser Directory for those <br />dispenser models which require the <br />use of product offsets. <br />