Laserfiche WebLink
BANKS & CO <br /> for preventing persons form entering the work site, excepting employees and other <br /> persons involved in the performance of the work. <br /> ' Banks & Co. has the responsibility for compliance with safety and health <br /> standards prescribed under the California Occupational Safety and Health Act, <br /> ' California Administrative Code, Title 8. <br /> It shall be Banks & Co. responsibility to keep the excavated work site <br /> barricaded or closed to prevent entry by unauthorized persons, to be responsible <br /> for passage of Banks & Co. personnel or equipment, and to assure that those <br /> permitted to enter are aware of the hazards and familiar with the safety <br /> precautions to be followed. <br /> Specific Requirements: <br /> ' 1 . A temporary barricade shall be erected a minimum of 6 feet from the outer <br /> expected limit for excavation activities. The barricade will consist of <br /> a minimum 4 feet high continuous barrier. Signs will be erected stating, <br /> "NO SMOKING" . <br /> 2. Appropriate Personal Protective Equipment, hard hats, safety glasses and <br /> steel-shank and toed boots must be worn at all times within the barricaded <br /> area. <br /> Banks & Co. shall conduct operations to avoid closing or obstructing any <br /> portion of any highway, road or other property until permits have been obtained <br /> from the proper authorities. If any of the above are required to be kept open <br /> or shall be rendered unsafe by tank removal procedures, Banks & Co. shall make <br /> such repairs and provide such temporary guards, bridges, lights and other signals <br /> as necessary. These shall be acceptable to the authorities having jurisdiction <br /> and to the site inspector. Banks & Co. shall make all necessary arrangements for <br /> the protection on the convenience of pedestrian traffic along the construction <br /> ' site, including temporary access to all business establishments, and pedestrian <br /> walkways as required by the site inspector. <br /> 6.2 FIRE PROTECTION AND SUPPRESSION <br /> Banks & Co. shall take all reasonable precautions to prevent fires on the <br /> work, and in the general vicinity of our operations, and shall be reasonable for <br /> all damages from fires due directly or indirectly to Banks & Co. 's own <br /> activities, our subcontractor's or our employees. Banks & Co. shall maintain all <br /> work areas free from unnecessary combustibles and obstructions to fire fighting <br /> access. <br /> Specific Requirements: <br /> 1 . No smoking or ignition sources of any type will be allowed within a <br /> 50 foot perimeter of the project site. <br /> 2. A minimum of two (2) , 30 lb. Class A,B,C Fire Extinguisher must be <br /> easily accessible within the barricaded area at all times. <br /> g SITE SAFETY PLAN <br />