My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO 2012 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:11:02 PM
Creation date
11/6/2018 10:35:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2014
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306026
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PESCADERO\1535\PR0232495\COMPLIANCE INFO 2012 - 2014 .PDF
QuestysFileName
COMPLIANCE INFO 2012 - 2014
QuestysRecordDate
12/8/2016 9:18:09 PM
QuestysRecordID
3274874
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
153
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 1 oft <br /> 6.PIPING SUMP TESTING <br /> Test Method Developed By: F Tank Manufacturer P� Industry Standard ❑ Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: h Pressure Vacuum Hydrostatic <br /> F Other(Specify) <br /> Test Equipment Used: VPLT Equipment Resolution: 0.00001 in. <br /> STP Containment for STP Containment for STP Containment for STP Containment for <br /> Tank motor oil Tank gear oil GEAR Tank waste oil tank Tank and freeze <br /> MOTOR OIL-1 OIL-1 ad WASTE OII,-1 ANTIFREEZE-1 <br /> Sump Diameter/Dimensions: 48 in. 48 in. 48 in 48 in. <br /> Sump Depth: 68.00 in. 73.00 in. 56.00 in. 73.00 in. <br /> Sump Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 36.00 36.00 18.00 36.00 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 1 <br /> Electrical Penetration: 3.00 10.00 58,00 10.00 <br /> Condition of sump prior to testing: good good good good <br /> Portion of Sump Tested' 38 38 20 38 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both f' Yes 9 No 4; NA Pd Yes 6 No IT NA 91 Yes 0 No Q NA 40 Yes 0 No M NA <br /> product and water)?* <br /> Turbine shutdown response time 02:00:00 sec 02:00:00 sec 02:00:00 sec 02:00:00 sec <br /> Is system programmed for fail-safe it Yes 9 No 6 NA 0 Yes Ot No d; NA P Yes 4 No 0 NA 91 Yes fV No R NA <br /> shutdown?* <br /> Was fail-safe verified to be r Yes C No R <br /> operational?* NA 07Yes a No Eat NA 0 Yes f No 0NA F( Yes 40 No 42 NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min 5 min 5 min <br /> test <br /> Test Start Time: 10:51:00 10:51:00 11:47:00 11:47:00 <br /> Initial Reading(RI): 0.00000 in. 0.00000 in. 0.00000 in. 0.00000 in. <br /> Test End Time: 11.21:00 11:21:00 12:17:00 12:17:00 <br /> Final Reading(RF) -0.00130 in. -0.00170 in. -0.00120 in. -0.00090 in. <br /> Test Duration: 30 mint 30 min 30 min 30 min <br /> Change in Reading(RF-RI)- -0.00130 in. -0.00170 in. -0.00120 in. -0.00090 in. <br /> Pass/Fail Threshold or Criteria: +h 0.00200 +/-0.00200 —'-0.00200 '/-0.00200 <br /> Test Result: - Pass Pass Pass Pass <br /> Was sensor removed for testing? r Yes{" No C NA F Yes r No C VA (•' Yes C Nor NA /+• Yes F' No t' NA <br /> Was sensor property replaced and G Yes C` No C NA f>n Yes C No(r NA 9 Yes a No C NA Rd Yes No 4# NA <br /> veri£ed functional after testin <br /> COIIIIIIetltS-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> u/o sump near rack was not tested due to bad secondary line boot <br /> ' If the entire depth of the sump is not tested,specify how much was tested.If the answer to any of the questions indicated with an <br /> asterisk M is"NO"or"NA",the entire sump must be tested. <br /> WO:2314332 <br />