My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
4101
>
2200 - Hazardous Waste Program
>
PR0514403
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2019 11:54:44 AM
Creation date
11/6/2018 8:36:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514403
PE
2220
FACILITY_ID
FA0010747
FACILITY_NAME
South Bay Auto Auction
STREET_NUMBER
4101
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
Way
City
Stockton
Zip
95206
CURRENT_STATUS
02
SITE_LOCATION
4101 S Airport Way
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
FRuiz
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\A\AIRPORT\4101\PR0514403\COMPLIANCE INFO 1995 - 2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
H — <br /> I PHASE 1 ENVIRONMENTAL SITE ASSESSMENT <br /> 4101 S. Airport Way, Stockton, CA <br /> August 2009, Page 8 of 15 <br /> 4.7 Database Review <br /> We attempted to obtain Sanborn maps for the subject property,but none were found for the <br /> target property as indicated in the EDR Sanborn Map Report(Ref. 6; Appendix Q.The <br /> EDR database report had no entries for the subject property. <br /> 4.8 Liens, Deed Restrictions, and Environmental Compliance Activities <br /> A representative of the property owner(Ref. 5) stated that they were not aware of any liens <br /> on the subject property or deed restrictions related to environmental issues. They also <br /> stated that there have not been any dealings with the City of Stockton or the California <br /> Regional Water Pollution Control Board regarding any contamination at the property. <br /> 4.9 Other Issues <br /> During the site inspection, floor drains were observed in the main building(photo 8, <br /> Appendix A). According to the facility manager(Ref. 5) and confirmed by viewing <br /> original site drawings,the floor drains are connected to the septic system and were <br /> installed when the building was constructed in the 1950s. Floor drains were observed in <br /> the former shop area,boiler room, restrooms,and training rooms. <br /> Information obtained during the Phase I screening interview indicated that an asbestos <br /> survey of the facility was completed by ATC Associates, Inc. in August 2007. According <br /> to the facility manager,a small amount of friable asbestos was then removed. Any <br /> remaining asbestos containing materials were determined to be in good condition and were <br /> still in place at the time of the Phase 1 reconnaissance(photo 13,Appendix A). According <br /> to the asbestos survey report,the estimated cost to abate the remaining asbestos is <br /> approximately$70,000. A copy of the report is provided in Appendix D. <br /> A stormwater detention pond is located near the northern property boundary,between the <br /> facility parking area to the south, Industrial Drive to the north,and facility access roads to <br /> the east and west(photo 12,Appendix A). The pond is believed to have been built between <br /> 1970 and 1982. During the site reconnaissance,the pond was dry and devoid of vegetation. <br /> The vegetation was recently treated using Vegetation Manager SFM 75,a broadleaf weed <br /> and grass controller.A copy of the specimen label is provided in Appendix E. The active <br /> ingredient in this product is sulfometuron methyl. Although the present weed control <br /> activities are not considered to be a recognized environmental condition,previous <br /> applications of now banned substances could have occurred at this location prior to the use <br /> of SFM 75. <br />
The URL can be used to link to this page
Your browser does not support the video tag.