My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1992
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
2650
>
2300 - Underground Storage Tank Program
>
PR0232573
>
INSTALL_1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 11:53:13 AM
Creation date
11/8/2018 9:39:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1992
RECORD_ID
PR0232573
PE
2361
FACILITY_ID
FA0003941
FACILITY_NAME
ORCHARD SUPPLY HARDWARE #1570
STREET_NUMBER
2650
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21307061
CURRENT_STATUS
02
SITE_LOCATION
2650 MACARTHUR DR STE A
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MACARTHUR\2650\PR0232573\INSTALL 1992.PDF
QuestysFileName
INSTALL 1992
QuestysRecordDate
8/2/2017 4:00:35 PM
QuestysRecordID
3544491
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2) When the inner tank is partially or completely full and <br /> the groundwater table is below the tank bottom. <br /> 3) When the inner tank is partially or completely full and <br /> the tank is partially or completely submerged in <br /> groundwater. <br /> f. The leak detection performance of the monitoring system shall <br /> be tested and verified by a qualified independent consultant <br /> to detect leaks as small as .05 gallons per hour with a 95% <br /> probability of detection and less than a 5% probability of a , <br /> false alarm. <br /> g. All monitoring equipment, including FRP reservoirs and <br /> electronic control shall be UL listed. <br /> h. If hydrostatically monitored, any solution used in the tank <br /> annular space shall have UL approval for compatibility with <br /> the tank. <br /> G. Accessories <br /> f <br /> 1. Anchor Straps: Provide glass fiber-reinforced plastic anchor <br /> straps for each tank shown. Number and location of straps shall <br /> be as specified by manufacturer. Each strap shall be capable of <br /> withstanding the buoyancy load for tank diameter as shown: <br /> 4 ft - 4,200 lbs. <br /> 6 ft - 18,000 lbs. <br /> 8 ft - 25,000 lbs. <br /> 10 ft - 32,000 lbs. <br /> Straps shall be standard as supplied by the tank manufacturer. <br /> 2. Certification Plate: Underwriters' Laboratory label shall be <br /> permanently affixed to each tank. <br /> 3. Flanged Manways <br /> a. Each tank shall be provided with a 22" inside diameter manway. <br /> b. All manways shall be furnished complete with UL listed <br /> gaskets, bolts, and covers. <br /> c. Manway risers shall be provided to provide access to the <br /> piping sup if required. <br /> d. Provide manhole ring and cover, rated for H2O loading, over <br /> the piping sump. <br /> e. Tanks shall be provided with 43" yJ factory installed <br /> containment collars around flange manways. <br /> 15.11-6 <br /> Food Plant Engineering, Inc. <br />