My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GLOSSARY <br /> Access opening Manway Rib <br /> On a water or wastewater tank,an access opening is a A manway is the flanged fiberglass opening(typically 22-inch, A rib is the fiberglass reinforcement integrally man ufac <br /> non-flanged,non-bolted opening designed to provide 30-inch or 36-inch in diameter)that provides access to the tured around the circumference of the tank and evenly <br /> personnel access to the interior of the tank. primary tank and/or is used for multiple service fittings that spaced along the length of the tank. <br /> Baffle are welded to a bolt-on steel manway cover. Secondary backfill <br /> On a water or wastewater tank,a baffle is a partition wall Monitor fitting Secondary backfill is the granular material conforming to <br /> that may extend the full tank height. On adouble-wall tank,a monitorfitting is the accessory the requirements listed in section 1 that may be used as <br /> Base Tank that provides access to the interstitial space. an alternative to primary backfill above the tank in some <br /> On a multicompartment fuel tank,a base tank is the Monitoring fluid conditions. <br /> compartment with two convex domed endcaps that serve Also referred to as"brine,'on a hydrostatically monitored Secondary tank <br /> as bulkheadsto another compartment. double-wall tank,monitoring fluid isthefluid that is added Asemndary tank is the second wall of a multiple-wall tank. <br /> Containment sumps to interstitial space.The monitoring fluid that we commonly Fora double-wall tank,this wall of the tank is visible from <br /> A containment sump is a single-wall or double-wall use is an approximately 30%calcium chloride solution that the exterior. <br /> enclosure to be installed above underground storage tanks. is dyed blue to help differentiate itfrom other fluids. Single-wall(SW)tank <br /> It is used as a termination point for piping and tank access Pressure relief valve A single wall tank is a tank having only one wall separating <br /> openings. A pressure relief valve is the valve that automatically opens its contents from the external environment. <br /> Double-wall(DW)tank at a set pressure to relieve pressure if it rises above the set Test manifold <br /> Adouble wall tank is a tank with a primary(inner)wall point. Atest manifold is an assembly of components including <br /> surrounded by a secondary(outer)wall,with a monitorable Pressure testing pipe fittings,nipples,valves,hose,pressure gauges and <br /> space between the primary wall and the secondarywall. Pressure testing is the use of air or inertgas pressure and pressure relief valve,used forcontrolling and monitoring <br /> Dry monitor fitting soapy water solution to create soap bubbles as an indica- pressure during a pressure test. <br /> On adry-monitored double-wall tank,a dry monitorfitting tion of a problem with the tank. TRUCHEK® <br /> is the accessory thatprovides access to the interstitial space. Primary backfill TRUCHEV is our patented hydrostatic,tank-monitoring sys- <br /> End compartment Primary backfill is rounded or crushed stone conforming to tem for double-wall tanks.It is an easy,reliable method for <br /> On a multicompartment fuel tank,an end compartment is the requirements listed in Appendix C. true continuous leak detection and tank-tightness testing. <br /> the compartmentwith one convex and one concave domed Primary tank Torque rating <br /> endcap. A primarytank is the inner tank(product storage tank)of a Torque rating is the maximum allowable rotational load <br /> Plat multiple-wall tank. that can be applied to tighten threads.The holt torque <br /> Flat is a common term used to described the area between Red Tank rating of flanged fiberglass fittings and manways on our <br /> the ribs on the outside of the tank. A red tank is a tank manufactured in the United States. tanks is 25 foot-pounds. <br /> Green Tank Reservoir Unattached riser <br /> Agreen tank is a tank manufactured in Canada. On a hydrostatically monitored double-wall tank,a reservoir An unattached riser is a chamberwith an open bottom <br /> Interstitial space <br /> isthe small expansion chamber atthe top of thetank used above the tank,with no attachmentto the tank. <br /> Also referred to as'interstice'or'annularspace,"an for monitoring thefluid level in the interstitial space. <br /> Interstitial space is the region between any two walls of a <br /> tank or tank accessory. <br /> FUEL TANK <br /> Manway Monitor Fitting Reservoir <br /> End Compartment Base Tank End Compartment <br /> Rib Flat <br /> WATER TANK Access Opening Baffle <br /> 02 GLOSSARY <br />