My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1206
>
2300 - Underground Storage Tank Program
>
PR0231175
>
COMPLIANCE INFO 2011 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:54:06 PM
Creation date
11/8/2018 9:42:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2017
RECORD_ID
PR0231175
PE
2361
FACILITY_ID
FA0001247
FACILITY_NAME
DP & DK Investments, Inc.
STREET_NUMBER
1206
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1206 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1206\PR0231175\COMPLIANCE INFO 2011 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2011 - 2017
QuestysRecordDate
4/9/2018 3:51:45 PM
QuestysRecordID
3847565
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑ Pressure ❑Vacuum ® Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: INCON SUMP TESTER Equipment Resolution:0.002" <br /> Sump#T-1 87 Sump#T-2 91 Sump#T-3 Diesel Sump# <br /> Sump Diameter: <br /> 42" 42" 42" <br /> Sump Depth: <br /> 59" 58" 53" <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 11„ 16" 16" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 17„ 26" 26" <br /> ENV! <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Dry Dry Dry <br /> Portion of Sump Tested' 2"/Penetrations 2"/Penetration 2"/Penetrations <br /> Does turbine shut down when DNA <br /> sump sensor detects liquid(both ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A NIA <br /> Is system programmed for fail-safe ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No [:INA <br /> shutdown?* <br /> Was fail-safe verified to be ❑yes ❑No ®NA [:]Yes ❑No ®NA ❑Yes ❑No ®NA [:]Yes ❑No ❑NA <br /> o erational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 10 min 10 min 10 min <br /> test: <br /> Test Start Time: 12:12pm 12:12pm 12:33pm <br /> Initial Reading(R,): 6.1221" 5.6567" 6.0325" <br /> Test End Time: 12:27pm 12:27pm 12:48pm <br /> Final Reading(RF): 6.1219" 5.6560" 6.0326" <br /> Test Duration: 15min 15min 15min <br /> Change in Reading(RF-Rj): -0.0002" -0.0007" +0.0001" <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +l-0.002" <br /> Test Result: ® Pass ❑Fail ® Pass ❑ Fail ®Pass ❑Fail ❑Pass ❑Fail <br /> Was sensor removed for testing? <br /> Eyes ❑No ❑NA ®Yes ❑No ❑NA Eyes ❑No ❑NA [:]Yes ❑No ❑NA <br /> Was sensor properly replaced and Eyes ❑No ❑NA Eyes ❑No [INA ®Yes ❑No [:INA ❑Yes ❑No ❑NA <br /> verified functional after testing?. <br /> Comments (include inormation on repairs made prior to testing and recommended follow-up for failed tests) <br /> ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to a�of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.