SWRCB,January 2002 <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC)TESTING <br /> Test Method Developed By: ❑UDC Manufacturer H Industry Standard ❑ Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum H Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: INCON SUMP TESTER Equipment Resolution:0.002" <br /> UDC#1-2 UDC#3-4 UDC#5 UDC#6 <br /> UDC Manufacturer: Bendel Bendel Bendel Bendel <br /> UDC Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> UDC De the 34" 34" 34" 34" <br /> Height from UDC Bottom to Top 12„ 12„ 92» 12" <br /> of Hi hest Pi in Penetration: <br /> Height from UDC Bottom to 14„ 14" 14" 14" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Dry Dry Dry Dry <br /> testing: <br /> Portion of UDC Tested' 2"/Penetrations 2"1 Penetrations 2"/Penetrations 2"/Penetrations <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No HNA ❑Yes ❑No H NA ❑Yes ❑No HNA ❑Yes ❑No HNA <br /> product and water)?* <br /> Turbine shutdown response time N/A NIA NIA N/A <br /> Is system programmed for fail- ❑No HNA ❑Yes ❑No HNA ❑Yes ❑No HNA ❑Yes ❑NJZNA <br /> safe shutdown?* ❑ es <br /> Was fail-safe verified to be ❑Yes ❑No HNA El Yes ❑No HNA ❑Yes ❑No HNA ❑Yes ❑N <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 10 min 10 min 10 min 10 min <br /> -startingtest <br /> Test Start Time: 11:46am 11:10am 9:45am 9:45am <br /> Initial Reading R,): 1.5027" 52345" 5.9948" 5.3593" <br /> Test End Time: 12:01 pm 11:25am 10:00am 10:00am <br /> Final Reading(RF): 1.5025" 5.2340" 5.9948" 5.3592" <br /> Test Duration: 15min 15min 15min 15minm <br /> Chane in Reading RF-R,): -0.0002" -0.0005" 0.000" -0.0001" <br /> Pass/Fail Threshold or Criteria: +l-0.002" +/-0.00211 +/-0.002" +/-0.002" <br /> Test Result: H Pass ❑Fail H Pass ❑Fail H Pass ❑Fail H Pass ❑ Fail <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ®Yes []No ❑NA ®Yes ❑No ❑NA ®Yes [:]No [:INA <br /> Was sensor properly replaced and H yes [—]No ❑NA H Yes ❑No ❑NA H Yes ❑No ❑NA H Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments (include information on repairs made prior to testing and recommended follow-up for failed tests) <br /> ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br /> n s nn � <br /> a. �H <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. If the answer to Any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />