My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2467
>
2300 - Underground Storage Tank Program
>
PR0231818
>
COMPLIANCE INFO 2002 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:06 PM
Creation date
11/8/2018 9:44:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2013
RECORD_ID
PR0231818
PE
2361
FACILITY_ID
FA0022456
FACILITY_NAME
Foodliner, Inc.
STREET_NUMBER
2467
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
Rd
City
Stockton
Zip
95205
APN
17130003
CURRENT_STATUS
02
SITE_LOCATION
2467 E Mariposa Rd
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2467\PR0231818\COMPLIANCE INFO 2002 - 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SW RCB,January 2002 f/ Page 6 o4 <br /> 8.4II.L RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps <br /> Fill Riser Containment Sumps are Present,but were Not Tesfed ❑ <br /> TFst Method Developed By: ❑Sump Manufacturer ❑Indust $tandard ❑Professional Engineer j <br /> ❑Other(Spec) <br /> Test Methd Used: D Pressure ❑Vacuum ❑Hydrostatic <br /> 7, ❑Other(Specify) <br /> Test Equipment Used; Equipment Resoluti <br /> ti <br /> .., Fill Sump# Fill Sum # Fill Sum # ' Fill Sump# <br /> Sump Diameter: <br /> Sump Depth: <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sump prior to <br /> testis : <br /> Portion of Sump Tested <br /> Sump Material: <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(Ri): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Chane in Reading RF-Rr : <br /> Pass/Fad Threshold or Crite ' : <br /> Test Result: ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Is there a sensor T the P7 ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No Yes ❑No <br /> Does the sensor al when <br /> either product or ater is ❑Yes ❑No ❑NA ❑Yes ❑No (INA ❑Yes ❑No ❑NA ❑Yes ❑NA <br /> detected? <br /> Was sensor movedfor testing2 ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes O No ❑NA ❑Yes ❑No NA <br /> Was sensor properly replaced and ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA No ❑ <br /> verified functional after testing? ❑Yes ❑ <br /> Comments—(include information on repairs made prior to testing and recommended ollow up forfalled tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.