My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO 2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 1:44:43 PM
Creation date
11/8/2018 9:52:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306026
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PESCADERO\1535\PR0232495\COMPLIANCE INFO 2004 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2004 - 2007
QuestysRecordDate
12/6/2016 12:58:59 AM
QuestysRecordID
3271591
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
339
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 2 of 5 <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: <br />O Tank Manufacturer.O <br />O Other (Specify) <br />Industry Standard O Professional Engineer <br />Test Method Used: <br />O Pressure <br />O Other (Specify) <br />OO Vacuum <br />O Hydrostatic <br />Test Equipment Used. <br />4-1/2 VACUUM <br />GAUGE JEquipment <br />Resolution: <br />+/_ 0.250/6 Accuracy <br />Tank # TCY1 <br />Tank # TCY7 <br />Tank # TCY2 <br />Tank # <br />Is Tank Exempt From Testing? <br />❑ Yes N No <br />N Yes ❑ No <br />N Yes ❑ No <br />❑ Yes ❑ No <br />Tank Capacity: <br />10000 <br />1000 <br />10000 <br />Tank Material: <br />DW FRP <br />DWF <br />DWF <br />Tank Manufacturer. <br />Product Stored: <br />Antifreeze <br />Gear Oil <br />Motor Oil <br />Waft time between applying <br />pressure/vacuum/water and <br />stating test: <br />10 min. <br />Test Start Time. <br />2:40 <br />Initial Reading (R,) <br />-10 <br />Test End Time. <br />3:40 <br />Final Reading (RF) <br />-10 <br />Test Duration: <br />60 min. <br />Change in Reading (R, -R,) <br />0 <br />Pass/Fail Threshold or Criteria: <br />+/-011 <br />Test Results: <br />N Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? R Yes ❑ No ❑ NA <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? R Yes ❑ No ❑ NA <br />❑ Yes ❑ No R NA <br />❑ Yes ❑ No R NA <br />❑ Yes [IND ❑ NA <br />Comments - (include information on repairs made prior to testing, and recommended follow-up failed tests) <br />TCX7..&..T.CX2.are..exem.ptn... !ai..tan.k..annular.s........................................ .................................... ............ ............................. <br />1 Secondary containment systems where the continous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic <br />containment testing. {Califomia Code of Regulations Title 23 Section 2637(a)(6)) <br />