My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2005 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 3:06:28 PM
Creation date
11/8/2018 9:59:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2008
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2005 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2008
QuestysRecordDate
8/2/2018 5:38:18 PM
QuestysRecordID
3952805
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 • • <br /> Page of <br /> S. FILI.RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps C <br /> Fill Riser Containment Sumps are Present,but were Not Tested U <br /> Test Method Developed By: ❑Sump Manufacturer n ladustryStandard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: L,Pressure C Vacuum i Hydrostatic <br /> ❑Odm(Spec1y) '( <br /> Teat Fguq meat Used: Equipment Resolution: �1 <br /> FBI Sump# Fill Sump# Fill Sump# I FlWump # <br /> S Diameter. <br /> S the <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sump prior to <br /> testin : <br /> Portion of Surnp Tested <br /> Sump Material: <br /> Wait time between applying <br /> ptessurdvacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Readi r): <br /> Test End Time: <br /> Final Reading <br /> Test Duration: .. <br /> ChanLe in Reading(RF-R : <br /> Pass/Fail Threshold or Criteria: <br /> Test Rteasilt: ❑ Paa ❑F D Pass tI FaU ❑ Pan 11 Fen ❑ Pus ❑Fall <br /> Is there a sensor in the sump? ❑yes flN6 jYes D No 11 Yes ❑No it Yes 1-1 No <br /> Does the sensor alarm when <br /> either product or water is IIYes UN fl NA ItYes ; :No UNA ❑Yes ".No CNA CYes UNo UNA <br /> detected? <br /> Was sensor removed for testing? fl Yes o C NA 0e tl No fl NA ❑Yes ❑No UNA ❑Yes I,NO ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? ❑Yes ❑No f..l NA I!Yes !:No I I NA : Yea 'No ❑NA U Ya I i No [7 NA <br /> COd MCRtS— (include infomation onoeparrs made prior to testing, and recommended ollow-up jorjailed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.