My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 4:48:12 PM
Creation date
11/8/2018 10:21:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2006-2012.PDF
QuestysFileName
COMPLIANCE INFO 2006-2012
QuestysRecordDate
7/5/2017 10:08:33 PM
QuestysRecordID
3482644
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 5 of 9 <br /> 7. UNDER-DISPENSER CONTAINMENT(UDC TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑ <br /> Pressure Vacuum ®Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: See attached testing procedures. — Equipment Resolution: <br /> UDC# 1/2 UDC #3/4 - U llC#5/6 _ � UDC#7/8 <br /> UDC Manufacturer. _ <br /> UDC Material: Plastic Plastic Plastic Plastic <br /> UDC Depth: 33" 33" 30" 30" <br /> Height from UDC Bottom to Top 10" 10" <br /> 10" 10" <br /> of Highest Piping Penetration: 5" <br /> Height from UDC Bottom to 4" 4" 5" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Fair Fah' Fair Fav <br /> testis <br /> Portion of UDC Tested Above highest Above highest Above highest Above Honest <br /> serration penetration penetration enetratlon <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No N NA ❑Yes❑No N NA ❑Yes ❑No N NA ❑Yes ❑No N NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- ❑Yes ❑No N NA ❑Yes❑No N NA ❑Yes ❑No N NA ❑Yes ❑No N NA <br /> safe shutdown? <br /> Was fail-safe verified to be ❑Yes ❑No N NA []Yes❑No N NA ❑Yes ❑No N NA ❑Yes ❑No®NA <br /> operational? <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test <br /> Test Start Time: 1:34pin 1:34pm Visual Fail 1:34pm <br /> Initial Reading(Rt): 2.5720 1.6555 2.9967 <br /> Test End Time: 1:49pm 1:49 m 1:49pm <br /> Final Reading(RF): 2.5721 1.6563 2.9968 <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Change in Reading(RF-R,): 0.00011 0.00079 0.00004 <br /> PassTail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: N Pass ❑Fail N Pass ❑Fail ❑ Pass N Fail N Pass [:] Fail <br /> Was sensor removed for testing? NYes [-]No ❑NA NYes❑No❑NA NYes❑No❑NA NYes❑No ❑NA <br /> Was sensor properly replaced and NYes <br /> verified functional after testis ? ❑No ❑NA NYes❑No❑NA NYes❑No❑NA NYes❑No ❑NA <br /> C0111I11entS-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> UDC 5/6-leak at jumper boot <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.