My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 4:48:12 PM
Creation date
11/8/2018 10:21:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2006-2012.PDF
QuestysFileName
COMPLIANCE INFO 2006-2012
QuestysRecordDate
7/5/2017 10:08:33 PM
QuestysRecordID
3482644
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 7 of 9 <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer IN Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: - ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: <br /> Fill Sump #87-1 Fill Sump #87-2 Fill Sump #91 __ Fill Sump <br /> Sump Diameter. 48" 48" _ 48" <br /> Sump Depth: 59" 52" _ 55" <br /> Height from Tank Top to Top of 12" 13" 12" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 24" 20" 20" <br /> Electrical Penetration: <br /> Condition of sump prior to Fair Fair Fair <br /> testing: <br /> Portion of Sump Tested Above highest Above highest Above highest Above highest <br /> penetration penetration penetration penetration <br /> Sump Material&Manufacturer: Fiberglass Fiberglass Fiber ass <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 10:26am 10:26am 10:21am <br /> Initial Reading(R,): 4.0194 3.2888 2.5652 <br /> Test End Time: 10:41am 10:41am 10:36am <br /> Final Reading(RF): 4.0200 3.2892 2.5657 <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Chane in Reading(RF-R,): 0.00062 0.00037 0.00050 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: ® Pass =Fail N Pass LJ Fall ® Pass El Fail Pass Fail <br /> Is there a sensor in the sump? ®Yes ❑No ®Yes No Yes No Yes No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes ❑No ®NA [-]Yes [-]No®NA ❑Yes ❑No®NA ®Yes ❑No❑NA <br /> detected? <br /> Was sensor removed for testing? ®Yes El No ❑ ®Yes El No <br /> ®Yes ❑No [INA ®Yes [-]No❑NA <br /> Was sensor properly replaced and NA NA <br /> EYes ❑No ❑NA Yes <br /> verified functional after testing? ® ❑No❑NA ®Yes ❑No❑NA ®Yes ❑No❑NA <br /> Comments—(include information on repairs made prior to testing and recommendedfollow-up forfailed tests) <br />