My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2023 9:08:35 AM
Creation date
11/8/2018 10:21:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2016 - PRESENT.pdf
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
416
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. UNDER-DISPENSER CONTAINMENT(UDC) TESTING <br /> Test Metfiod Developed By: ❑ UDC Ivlalt.4tfacturer ® Industq Standard ❑ ProfessionatEngincer <br /> ❑ Other(Specifu) <br /> Test Method Used: ❑Pressure ❑ Vacuum 0 Hydrostatic. <br /> p Other(Specify) <br /> Test Equipiiient Used: Incon TS-STS sump Test system Equ pMent Resolution: +/-0.902" <br /> UDC.# 112 UDC# &4 UDC# UDC 0 <br /> UDC Manufacturer: Environ Environ Environ )environ <br /> UDC Material: plastic Plastic Plastic Plastic <br /> UDC De the 34" 34" 30+' 30" <br /> Height from UDC Bottom to Top 11" 11" 11'+ IV <br /> of Highest Piping Penetration; <br /> Height from UDC Bottom to 5+' 5" 5" 5" <br /> Lowest EIectrical Penetration: <br /> Condition of UDC prior to <br /> testing: Good Good Good Good <br /> Portion of UDC Tested 4" Above p n 4" n 4" Above Pen, " A n <br /> Does turbine shut down when <br /> UDC sensor detects.liquid(both ❑Yes ❑ No E NA ❑ Yes ❑ No ®NA ❑ Yes.El No .0 NA ❑Yes 0 No ®NA <br /> product and-vvater)7` <br /> Turbine shutdown response time N/A NIA N/A NIA <br /> Is system programmed for fail- ❑ Yes❑TNo 2 NA ❑ Yes❑ No ®NA ❑ Yes❑No U.NA ❑Yes❑ No ®NA. <br /> safe shutdown?' <br /> Was failsafe 9erified.to be El Yes❑No 0 NA E❑ Yes❑No ®NA ❑ Yes❑No Z NA ❑Yes El Na. ®.NA <br /> o eration4ff <br /> Wait time bet-ween applying <br /> pressure/vacuuin/rvater.aild 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test <br /> Test Start Time: 11:26 AM 11:26 AM <br /> initial Reading(Rj): 4.2429 5.358 <br /> Test End Time: 11:41 AM 11:41 AM <br /> Final Reading(RF): 4.204 5.3573 <br /> Test Duration: 15 min. 15 min. 15 min. 15 min. <br /> C11FR in Readit1g(RF-Rl): -0.0389 -0.0007 <br /> Pass/Fail Threshold or Criteria: +/-0.002 +/-0.002 +/-0.002 +/-0.002" <br /> Test Result: Fail Visual Fail Pa" Visual Foil <br /> Was sensor removed.for testing? Yes Yes Yes Yes <br /> Was sensor properly replaced,and <br /> verified functional after testin 7 Yes Yes Yes Yes <br /> COmnlents— (include h?formaliojr on repairs made prlof to lesting, cad recoy+ruefadedLolloii-r(p fat-failed tests) ^� <br /> Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment Testing scope of work. <br /> -1/2 unable to locate leak. <br /> -3/4 and 7/8-torn penetrations. <br /> F. <br /> ENVIRONMENTAL HEALTH <br /> PERMITISERVICES <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to ate-of the questions indicated with an <br /> asterisk(*)is"NO"or"NX',the entire.UDC mus(be tested. (See 5WRCB LG-160)' <br />
The URL can be used to link to this page
Your browser does not support the video tag.