FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\E\ESCALON\1329\PR0231487\2017 INSTALL.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
445
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
▪ Brine addition and verification for brine leaks in the interstitial space of all sumps and <br />UDC(s) prior to backfill. (Completed for UDCs, vent sump, and STP sumps) <br />El Verification of communication for all installed vacuum, pressure, or hydrostatic (VPH) <br />components <br />O Verification of the dispenser footprints contained by the under dispenser containment <br />sumps (UDCs) (Completed) <br />El Enhanced Leak Detection (ELD) testing (after facility is in operating condition): <br />appropriate test notification and test method disclosure <br />O VPH components verification (lockable lids, shroud boots, band clamps, gaskets, <br />etc.) <br />LI Overfill prevention verification: Measurement of drop tubes to verify 95% tank volume <br />shut off and/or verification that external audible/visual alarm activates when tank is <br />90% full. <br />o Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic <br />test (or equivalent). Proper drainage method must be verified. <br />o Monitoring system functionality prior to fuel delivery: Functionality of the monitoring <br />system must be verified to ensure it meets the requirements of Title 23 California <br />Code of Regulations and the Health & Safety Code (functionality of brine and liquid <br />sensors in sumps and under dispenser containments (UDCs)). (Completed) <br />O Leak detector test: Leak detector must be tested to confirm that the device can <br />detect a leak of 3 gallons per hour at 10 psi. (Completed) <br />LI Verification of concrete thickness at the tanks for compliance with buoyancy <br />calculations. <br />O Fill sump integrity testing after repairs. <br />LI Visual inspection of the UDCs to verify construction is in a manner to prevent vapors <br />from entering the backfill. <br />LI Visual verification of adhesive removal from the 87 fill sump vacuum tube. <br />7 Verification of all fuel removal from 87 product, vent, and vapor recovery vacuum <br />monitored secondary piping; verification that primary piping is free of leaks. <br />O Monitoring system functionality: Functionality of the monitoring system must be <br />verified to ensure it meets the requirements of Title 23 California Code of <br />Regulations and the Health & Safety Code (functionality of vacuum and liquid "smart" <br />sensors). <br />Li Final inspection and demonstration of automatic shut-down, as applicable. <br />7. All USTs shall be anchored using deadmen as detailed in the permit application. <br />8. Install concrete of sufficient thickness according to the manufacturer's written installation <br />instructions. <br />9. Install all product and vent piping according to manufacturer's written installation <br />instructions; maintain all appropriate piping distances and installation depths. <br />10. All monitoring systems shall be listed in the State Water Resources Control Board's <br />Local Guidance Letter (LG) 113 letter. <br />Arco AM/PM, 1305 S. Escalon Ave., Escalon, CA 95209 SR0074800 3