My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
COMPLIANCE INFO 2002 - 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2019 2:07:54 PM
Creation date
12/4/2018 11:32:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2005
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page of <br /> 7. FILL RISER C ONNT_AI gWNT SVW TESTING <br /> Facility is Not Equipped With FillRiser Containmem Sums ❑ <br /> Fili:Riser Comainmeirtt Sumps are Present,but were Not Tested <br /> Test Method Developed By: ❑ Sump Manufacturer ❑Industry Standard ❑Professional Engine <br /> Other(Specify) <br /> Test Method Used: C Pressure ❑ Va = C Hydrostatic <br /> ❑'Other(SPec�&) <br /> Test Equipment Used: Equips R=oMoa <br /> Felt Swap# FM Sump# I Fill Sump# Fill Seemp# <br /> Sump Diameter- <br /> Sump <br /> iameterS <br /> Height from Tank Top to Top of— <br /> Righen Piping <br /> PeuetratiotL <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of mmP prior to <br /> Portion of Sump Tested + _ <br /> Sump Material: i <br /> Wait time between applying <br /> pressureJvaasim/water and ` <br /> tem: <br /> Test Start Time: <br /> Initial Reading(Pj): <br /> Test End Time: <br /> Final <br /> Test Duration: <br /> Change in Reading(Rr . <br /> PassTSA Threshold or Criteria <br /> Is there a sensor in the sump? ❑Yes !,No 0 Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> detected? <br /> Was -qensr_ removed far testing? Eyes ❑No ENAI Eyes ❑No NA ❑Yes ❑No ❑NA i]Yes ❑No DNA <br /> Was sensor proPerfY replaced and ❑Yes G No ❑NA ❑Yes ❑No ❑NA ❑Yes C No ❑NA ❑Yes :1 No ❑NA <br /> verified fimcdonal'af ff 1 <br /> Comments—(include information an repairs made prior to testing, and reconmwnded falla►v-up for furled tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.