Laserfiche WebLink
S A I D J O M Q V I N Environmental Health Department <br /> COU N7Y <br /> Food Program Official Inspection Report <br /> Facility Name and Address: ROUND TABLE PIZZA, 253 SPRECKELS AVE, MANTECA 95336 <br /> #33 Nonfood Contact Surfaces Clean <br /> OBSERVATIONS:The large CO2 tank by the soda syrups has syrup splatters on it. Clean within 2 weeks. <br /> The bottom shelf of the Artic Air freezer is very dirty with build up, debris, mold, and mildew. Clean and sanitize within 1 <br /> week. <br /> The top of the dishwasher is dirty. Clean within 2 weeks. <br /> The top of the oven is dirty. Clean within 2 weeks. <br /> CALCODE DESCRIPTION:All nonfood contact surfaces of utensils and equipment shall be clean. (114115(c)) <br /> #35 Equipment/Utensils Approved and in Good Repair <br /> OBSERVATIONS:The Artic Air freezer door does not completely close. Repair today. <br /> CALCODE DESCRIPTION:All utensils and equipment shall be fully operative and in good repair. (114175).All utensils and equipment <br /> shall be approved,installed properly,and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5, <br /> 114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182) <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:The vent covers are dirty with grease build up. Clean within 2 weeks. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft, or a <br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored,served,prepared,and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:The drain pipe at the 3 comp sink's floor sink does not have a 1 inch air gap. Raise or cut drain pipe to <br /> allow a 1 inch air gap. Correct within 2 weeks. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances,shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> FA0018244 PR0526931 SCO01 01/14/2019 <br /> EHD 16-23 Rev.06/30/15 Page 2 of 3 Food Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />