Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax.(209)468-3433 Web:www.smgov.or.q/ehd/unitiii.htmi <br /> CONTINUATION FORM Page: 5 of 6 <br /> OFFICIAL INSPECTION REPORT Date: 4/20/2010 <br /> Facility Address: 511 N Airport Way, Manteca Program: APSA <br /> SUMMARY OF VIOLATIONS <br /> a (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> #19, Facility failed to include description of product type and storage capacity for each container as <br /> required by CFR 112.7(a)(3)(1). Immediately, include the description of product type and storage <br /> j capacity in the SPCC plan and keep a copy at the facility for record and review. <br /> #20. Facility failed to include procedures for routine handling of product and discharge prevention <br /> measures as required by CFR 112.7(a)(3)(ii). Immediately, include procedures of routine handling.of <br /> products and discharge prevention measure in the SPCC plan and keep a copy for record and review. <br /> #21, 22 and 23. Facility lack discharge and drainage control for the secondary containment as required <br /> by CFR 112.7(a)(3)(iii), failed to show countermeasure for discovery, cleanup and discharge as required <br /> by CFR 112.7(a)(3)(iv) and failed to address disposal method for discovered material as required by <br /> CFR 112.7(a)(3)(v). Immediately, provide discharge and drainage control and also include the <br /> discharge procedure in the SPCC plan, provide countermeasure for discovery cleanup and discharge in <br /> the SPCC plan. <br /> I #24 and 25, Facility lack a required contact list and phone numer of the response coordinator as <br /> requited by 112.7(a)(3)(vi) and also failed to provide procedure to enable a person to adequately report <br /> discharges as required by CFR 112.7(a)(4). Immediately, provide the required contact list and the <br /> phone number of the facility's response coordinator and provide information and procedures to enable a <br /> person to adequately report discharges and include it in the SPCC plan for record and review. <br /> #27. Facility failed to include a description of potential equipment failure as required by CFR 112.7(b). <br /> Immediately, include a description of potential equipment failures in the SPCC plan. <br /> #28. Facility does not have secondary containment for the tanks or piping ( pipe was leaking at the time <br /> of inspection). Facility failed to provide secondary containment to the tank system or diversionary <br /> structures that are capable of containing discharge from primary containment until cleaned up. <br /> Immediately provide secondary containment for the tank and the tank system. <br /> #29 and 31. Facility failed to provide periodic inspection and testing of tank and tank system or keep <br /> records. Pursuant to CFR 112.7(d) a facility must provide perodic intergrity testing of tanks, valves and <br /> pipings periodically and pursuant to CFR 112.7(e) conduct periodic inspection and tests and keep j <br /> records as specified in the SPCC. <br /> #32. Facility lack personnel training and annual breifing for discharge prevention. Immediately, provide <br /> training for all personeel and alsonprovide annual breifing as required by CFR 112.7(f). <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($115). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD inspector: Received By: Title: <br />