3.0 PROPOSED SCOPE OF WORK <br /> 3.1 APPROACH <br /> 1. To monitor the quality of the ground water at the site,one upgradient ground water monitoring <br /> well (MW-1) and three downgradient monitoring wells (MW-2, MW-3 and MW-4) will be <br /> installed and monitored. MW-I will be located near the southwest property boundary (see <br /> Figure 2 for approximate Iocation of the well). It is anticipated that MW-1 will provide data to <br /> evaluate the ground water quality on the upgradient side of the OWS and evaporation pond. <br /> MW-2 will be located downgradient from the OWS_ MW-3 and MW-4 will be located <br /> downgradient from the evaporation pond- <br /> 2. MW-1 is proposed at a location that is: <br /> Upgradient from the site and is located on BNSF property. <br /> • Located far enough upgradient so that it is expected to be outside of the <br /> zone of influence of any leak from the evaporation pond_ <br /> 3. MW-2 is proposed at a location that is- <br /> • Downgradient of the OWS. <br /> • Placed approximately 100 feet from the center of the OWS to represent <br /> the full zone of potential influence- <br /> Located in an area that will be relatively accessible and not impact the <br /> operations of the facility. <br /> 4. MW-3 is proposed at a location that is: <br /> ! Downgradient of the evaporation pond. <br /> ! Placed approximately 100 feet from the center of the evaporation pond to <br /> represent the full zone.of potential influence. <br /> • Located in an area that will be relatively accessible and not impact the <br /> operations of the facility. <br /> 5. MW-4 is proposed at a location that is: <br /> • Downgradient of the evaporation pond. <br /> • Located further downgradient than MW-3,to serve as an evaluation point <br /> should a release be detected at MW-3. <br /> Located in an area that will be relatively accessible and not impact the <br /> operation of the facility. <br /> TRC <br /> lut ons <br /> 90'd S0:8 10, q upr <br />