My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACACIA
>
501
>
2900 - Site Mitigation Program
>
PR0508319
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2019 5:15:32 PM
Creation date
2/1/2019 4:25:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0508319
PE
2950
FACILITY_ID
FA0008031
FACILITY_NAME
FORTIFIBER
STREET_NUMBER
501
Direction
E
STREET_NAME
ACACIA
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
501 E ACACIA ST
P_LOCATION
01
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ljeo 0ica(Technics Inc. Page 2 <br /> Rehrig Pacific Inc. <br /> Phase II ESA Report <br /> Project No.: 709.2 <br /> January 4, 1999 <br /> ' 5. Two soil samples per borehole were submitted to Sherwood labs and tested for TEPH-D <br /> MO by EPA method 8015m and Halogenated Solvents by EPA method 8010. <br /> ' Former Underground Storage Tanks <br /> 1. A hole was cored through the asphalt surface of the tank excavation. <br /> ' 2. A borehole was attempted by hand auger methods but could not be advanced because the <br /> excavation had been backfilled with pea gravel. <br /> 3. A new hole was cored through the asphalt along the western side of the excavation <br /> 4. One borehole (HB-8) was drilled by hand auger methods to the capillary fringe, <br /> approximately 7 feet bgs. <br /> 5. The borehole was logged for the geologic properties, discoloration and any unnatural <br /> odor as observed in the drill cuttings that are removed during the drilling process. <br /> ' 6. A soil sample was collected at the bottom of the borehole. <br /> 7. The borehole was grouted up with neat cement grout under the supervision of Lori <br /> Duncan of SJC PHS/EHD. <br /> ' 8. The soil sample was submitted to Sherwood labs and tested for BTEX by EPA method <br /> 8020, TPH-G by EPA method 5030/8015m, TEPH-D, MO by EPA method 8015m. <br /> Waste Storage <br /> 1. Several areas around the storage area that had visible oil staining were investigated. The <br /> rock surfacing was pulled back and boreholes were advanced by hand auger methods to <br /> determine the heaviest stained area. <br /> 2. One borehole (HB-9) was drilled through the area of heaviest staining by hand auger <br /> methods to 5.5 feet bgs. <br /> 3. The borehole was logged for the geologic properties, discoloration and any unnatural <br /> ' odor as observed in the drill cuttings that are removed during the drilling process. <br /> 4. A soil sample was collected at 1-foot bgs and the bottom of the borehole. <br /> 5. The borehole was grouted up with neat cement grout under the supervision of Lori <br /> Duncan of SJC PHS/EHD. <br /> ' 6. Two soil samples were submitted to Sherwood labs and tested for TEPH-D, MO by EPA <br /> method 8015m and Halogenated Solvents by EPA method 8010. <br /> ' 55 Gallon Drums & Staining <br /> 1. Several areas around the storage area that had visible paint staining were investigated. <br /> The rock surfacing was pulled back and boreholes were advanced by hand auger methods <br /> to determine the heaviest stained area. <br /> ' 2. One borehole (HB-10) was drilled by hand auger methods to 3 feet bgs. <br /> 3. The borehole was logged for the geologic properties, discoloration and any unnatural <br /> odor as observed in the drill cuttings that are removed during the drilling process. <br /> 4. A soil sample was collected at the bottom of the borehole. <br /> 5. The borehole was grouted up with neat cement grout under the supervision of Lori <br /> Duncan of SJC PHS/EHD. <br /> 6. The soil sample was submitted to Sherwood labs and tested for Halogenated Solvents by <br /> EPA method 8010. <br />
The URL can be used to link to this page
Your browser does not support the video tag.