WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BETHANY
>
17103
>
2900 - Site Mitigation Program
>
PR0524391
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 5:44:02 PM
Creation date
2/7/2019 3:58:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0524391
PE
2965
FACILITY_ID
FA0016362
FACILITY_NAME
MOUNTAIN HOUSE WWTP
STREET_NUMBER
17103
Direction
W
STREET_NAME
BETHANY
City
TRACY
Zip
953917301
CURRENT_STATUS
01
SITE_LOCATION
17103 W BETHANY
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> Additional Groundwater and Agriculture Drain Monitoring Work Plan <br /> Residential Neighborhood G <br /> April 18,2005 <br /> Page 6 <br /> Table 1B: Agricultural Drain and Shallow Well Monitoring Sample Plan <br /> Type Methods Size'of Container Preservatives Holding Times <br /> Ammonia Nitrogen Grab 350.2 500mL plastic None(See note) 28 days with preservative- <br /> ASAP without preservative <br /> Nitrate Nitrogen Grab 300 1 Liter(combined with EC) <br /> g plastic or glass None 48 hours <br /> Total Nitrogen Grab 3513 28 days with preservative- <br /> g 500mL plastic None(See note) <br /> (TIIN+N) ASAP without preservative <br /> Electrical Conductivity Grab 120.1 1 Liter(combined with Nitrate) None 28 days <br /> plastic or glass y <br /> Total Coliform Organism Grab 9221B 125mL None 6 hours <br /> BOD Grab 5210B 1 Liter None 48 hours <br /> Note:If sample is not analyzed promptly,the sample must be preserved with H,SO4. <br /> 5.0 ADDITIONAL AGRICULTURAL DRAIN MONITORING <br /> 5.1 AGRICULTURAL DRAIN MONITORING LOCATION IDENTIFICATION <br /> Two down-gradient and three up-gradient agricultural drain monitoring points are shown on Figure;3. <br /> Down-gradient locations are located east of the Kelso Road Berm, where the irrigation drainage enters <br /> valved culverts to flow under the Kelso Road Berm into an irrigation drainage ditch west of the Kelso <br /> Road Berm(18A and 19A). <br /> Upstream agricultural drain samples will be taken as close to the identified locations (15A, 16A and 17A) <br /> as possible based on available water in the drains. If insufficient water exists in the drains at the proposed <br /> locations, the sample technicians will move downstream(north) until sufficient water is available, even if <br /> this is within the reclamation area. Sampling documentation will note the actual location of the upstream <br /> sample when that location varies from the mapped location. <br /> 5.2 SAMPLING FREQUENCY <br /> Agricultural drain monitoring points will be sampled monthly during the first year. Following the first <br /> year of sampling the agricultural drain monitoring points will be sampled quarterly. The sampling events_ <br /> will be coordinated with and conducted at the same time as the sampling of the agricultural drain <br /> monitoring points for the two existing reclamation areas. <br /> 5.3 SAMPLING PROCEDURES <br /> All sampling equipment will be cleaned prior to use by washing in a solution of laboratory-grade, non- <br /> phosphate detergent and deionized water, wiping with isopropyl alcohol, and double-rinsing with <br /> deionized water. Water samples will be collected from the ditch sampling locations by filling a Teflon <br /> dipping cup and transferring the water to laboratory-supplied containers. The sample containers will be <br /> labeled, placed in a cooler chilled with ice, and delivered in accordance with chain-of-custody procedures <br /> to a certified laboratory. <br /> es <br /> +', CONDOR <br />