My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2009 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:35:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2012
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
379
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JAN -20-2009 09:34 Service Station Systems 408 938 8888 P.10 <br />10. UNDER-DISPi,,NSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: M UDC Manufacturer ® Industry Standard [j Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ PressLLre p Vacuum ® Hydrostatic <br />El Other (Specify) <br />Test Equipment Used: Incon Sump <br />Tester <br />m <br />Equipment Resolution: +/- 0.002" <br />UDC # 17/18 UDC # 19/20 <br />UDC Manufacturer: <br />Western fiberglass <br />Weston fiberglass <br />UDC Material: <br />Fiber lass <br />Fiberglass <br />UDC Depth: <br />31" <br />31" <br />Height from UDC Bottom to Top <br />of Hi hest Pi _ in Penetration: <br />1 ? <br />12 <br />Height from UDC Bottom to <br />13" <br />13" <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Good <br />Good <br />testing: <br />Portion of UDC Tested <br />2" above eiping <br />2" above piping <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No UNA <br />product and water)?* <br />Turbine shutdown res onse time <br />N/A <br />N/A <br />Is system programmed for fail- <br />L] Yes [jNo®N�� <br />Ll Yes El No ®N�1 <br />safe shutdown?' <br />Was fail-safe verified to be <br />❑Yes C]No ®NA <br />❑Yes ❑ No ®NA <br />operational?' <br />Wait time between applying <br />pressure/vacuum/water and <br />30 minutes <br />30 minutes <br />starting test <br />Test Start Time: <br />1:08 pm <br />1:08 pm <br />Initial Reading (R,): <br />3.9638 <br />2.8520 <br />Test End Time: <br />1:23 pm <br />1:23 pm <br />Final Reading (Rt): <br />3.9633 <br />2.8508 <br />Test Duration: <br />15 min. <br />15 min. <br />Change in Reading (RF -R,): <br />-0.0005 <br />-0.0012 <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+1-0.00-1 <br />Test Result: <br />El Pass Fail <br />21 Pass Fail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />0 Yes ❑ No ❑ NA <br />I <br />! ® Yes p No ❑ NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended_fbllorv-up.Jor.f(ziled tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />1 If the pntirP deptLof the L= isnnttested specify how uutcJx_wasteUed_ If ewes to hof the 4uestinns irifliic:a2�tdwithau <br />aste[isk (*) is "NO" or "t4X'. theepfim,.L>_DC must be testees (See SWRCB LCs -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.