Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, CA95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209)464-0138 Web:www.sogov.org/ehd <br /> ��FOR <br /> Food Program Official Inspection Report <br /> Facility Name and Address: DENNYS RESTAURANT#8031, 2670 W MARCH LN, STOCKTON 95207 <br /> #38 Approved I Sufficient Ventilation and Lighting <br /> OBSERVATIONS: Couple of lights at cooks station lack sleeve covers. provide by 1 week. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment. All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a <br /> light-switch activated exhaust fan, consistent with local building codes.(114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 1141493, 114252, 114252.1) <br /> #39 Thermometers Provided/Accurate/Easily Visible <br /> OBSERVATIONS: Some coolers lack thermometers. Provide one for each unit. <br /> CALCODE DESCRIPTION:An accurate easily readable metal probe thermometer suitable for measuring temperature of food shall be <br /> available to the food handler. A thermometer+/-2#F shall be provided for each hot and cold holding unit of potentially hazardous foods <br /> and high temperature warewashing machines. (114157, 114159) <br /> #41 Plumbing Maintained; Approved Back Flow Device <br /> OBSERVATIONS: Prep sink lacks cold water. Repair issue, immediately. <br /> Water leak under one dipper well at waitress line. Repair by 1 week. <br /> CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device, as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose.(114171, <br /> 114189.1, 114190, 114193, 1141931, 114199, 114201, 114269) <br /> #45 Floors, Walls, Ceilings; Clean and Maintained <br /> OBSERVATIONS: Some hard to reach floor are not clean. Detail clean in walk in cooler, dry storage, ect. by 1 week and as <br /> needed. <br /> Small ceiling spot at ware washing was repaired but never painted. Paint by 1 week. <br /> CALCODE DESCRIPTION: The walls/ceilings shall have durable, smooth, nonabsorbent, light-colored, and washable surfaces. All floor <br /> surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily <br /> cleanable. Approved base coving shall be provided in all areas, except customer service areas and where food is stored in original <br /> unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143(d), <br /> 114266, 114268, 114268.1, 114271, 114272) <br /> FA0002035 PRO160489 SCO01 04/11/2016 <br /> EHD 16-23 Rev.06/30/15 Page 2 of 3 Food Program OIR <br />