My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 9:57:59 AM
Creation date
4/29/2019 11:40:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FEB-25-2011 15 38 Service Station Systems 408 938 8888 P.08 <br /> 8 . FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer 0 Industry Standard ❑ Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ® Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: [neon Sump Tester Equipment Resolution: +/-0,002" <br /> -ME' Fill Sump 0 87 , Fill Sum, i#89 Fill Sump t#91 <br /> "'� <br /> Sum Diameter: 42" 42" 42" <br /> Sump Depth: 63_-.�. _ 63" 63" <br /> Height from Tank Top to Top of N/A N/A N/A <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest <br /> 191, 19" 19" <br /> Electrical Penetration: <br /> Condition of sump prior to Good Good Good <br /> testing: I <br /> Portion of Sum Tested 2"above i inti- 2"above piping 2"above piping <br /> Sump Material: Fiber lass Fiberglass Fibers <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 8:12 am 8:12 am _ 8:12 am _ <br /> Initial Reading(Ri): 3.5699 3.4310 3.0389 <br /> Test End Time: 8:27 am 8:27 am 8:27 am _ <br /> Final Reading(RF): 3.5701 j 3.4308 3.0387 <br /> Test Duration: 15 min. j 15 min, E IS min. <br /> Chane in Reading(R--R,): +0.0002 �r -0.0002 -0.0002 <br /> Pass/Fail Threshold or Criteria: j +/-0.002" +/-0.002" i _ +/-0.002" <br /> Test Result: ; 0 Pass 0 Fail 0 Pass ❑ FailLE Pass ❑ Fail <br /> Is there a sensor in the sump? ® Yes ❑No ® Yes ❑No ® Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑ Yes ❑No ®NA ❑Yes ❑No ®NA ❑ Yes ❑No ®NA <br /> detected? i <br /> Was sensor removed for testis? ®Yes ❑No [INA ®Yes ❑No ❑NA ® Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> ® Yes <br /> verified functional after testing? ❑No E]NA ® Yes []No ❑NA ❑ Yes [I No [INA <br /> Comments— (include infbrmalion on repairs made prior to lesting, and recommended follow-up for failed tests) <br /> "Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />
The URL can be used to link to this page