My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2007 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 4:44:25 PM
Creation date
5/7/2019 4:02:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2009
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 6 of 10 <br /> 6. PIPING SUM IP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Spew) <br /> Test Method Used: 0 Premure ❑Vacuum X Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: lncon TS STS Equipment Resolution: <br /> Sump—R.P.S. Sump—P.P.S. Sump- Sump- <br /> Sump Diameter: 42" 42" <br /> Sump Depth- 60" 64" <br /> Sump Material: Fiberglass I Fiberglass <br /> Height from Tank Top to Top of 12" 121, <br /> Highest Pipipj Penetration: <br /> Height from Tank Top to Lowest 2211 23„ <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Clean Clean <br /> Portion of Sump Tested' I Full Full <br /> Does turbine shut down when <br /> sump sensor detects liquid(both X Yes 0 No 1 NA X Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> product and water?* <br /> Turbine shutdown response time 2 Seconds 2 Seconds <br /> Is system programmed for fail-safe X Yes ❑No ❑NA X Yes F_-No C NA ❑Yes ❑No ❑NA ❑Yes ❑No 0 NA <br /> shutdown?' <br /> Was fail-safe verified to be X Yes []No ❑NA X Yes ❑No ❑NA n Yes ❑No 01 NA ❑Yes ❑No ❑NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 minutes 15 minutes <br /> test: <br /> Test Stan Time: 11:21 11:21 <br /> Initial Reading(R0: 6.3062" 6.3528" <br /> Test End Time: 11:36 11.:36 <br /> Final Reading(RF): 6.3057' 6.3521" <br /> Test Duration: 15 minutes 15 minutes <br /> Change in.Reading(RF-R,): Loss.0005" Loss .0007' <br /> Pass/Fail Threshold or Criteria: Loss<.002"=pass Loss<.002"amass <br /> Teen Result: X Pass ❑Fail X Pass ❑Fail [2 Pass D Fall D Pass ❑Fail <br /> Was sensor removed for testing? X Yes ❑No ❑NA X Yes 0 No 0 NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and X Yes ❑No ❑NA X Yes ❑No [INA 0 Yes ©No 1--INA ❑Yes 7-No DNA <br /> verified functional after testing? <br /> COxI Ments—(include inf,? nTq ion on repairs made prior to testing and recomm@ndedfollow-up for failed tests1 <br /> Install new SSI test boots at the ends of all of the piping rens in the sumps and UDC's <br /> Verify that they have no leaks with soapy water. Tightest all clamps on the entries including the electrical. <br /> Plug the opening in the transition boot of the rock guard. <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to my of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SV,RCB LG-160) <br />
The URL can be used to link to this page