COMPLIANCE INFO 2008 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2008 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:02:33 PM
Creation date
5/15/2019 2:15:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2011
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAR-23-2010 09:53 Service Station Systems 408 938 8888 P.06/11 <br /> 6. SECONDARY PIPE TESTING <br /> Test Method Developed by: ❑ Piping Manufacturer ® Industry Standard p Professional Engineer <br /> ❑ Other(Spec) <br /> Test Method Used: M Pressure ❑ Vacuum ❑ Hydrostatic <br /> ❑ Other(Spec) <br /> Test Equipment Used: Test reducer boots,Nitrogen and gauges Equipment Resolution: 0.5%of span <br /> Piping Run#DSL—A Piping Run#DSL—B Piping Run#87 vent Piping Run#91 vent <br /> Piping Material: Plastic Plastic Plastic Plastic <br /> Piping Manufacturer: Western Fiberglass Western Fiberglass Western Fiberglass Western Fiberglass <br /> Piping Diameter: 2" 2" Z" 2" <br /> Length of Piping Run: 100' 100' 100' 100' <br /> Product Stored: Diesel Diesel N/A N/A <br /> Method and location of Reducer Rmts/Fettiugs Reducer nnots/Fittings Reducer Boots/Fittings Reducer RootdF'nttngs <br /> piping-run isolation: <br /> Wait time between applying <br /> pressure/vacuunt/water and 10 minutes 10 minutes 10 minutes 10 minutes <br /> starting test: <br /> Test Start Time: 10:30 am 10:30 am 10:30 am 10:30 am <br /> Initial Reading(Rt): 5 psi 5 psi 5 psi 5 psi <br /> Test End Time: 11:30 am 11:30 am 11:30 am 11:30 am <br /> Final Reading(Rr): 5 psi 5 psi 5 psi 5 psi <br /> Test Duration: 1 hr. 1 hr. I hr. i hr. <br /> Change in Reading(RF-Ri): none none none none <br /> Pass/Fail Threshold or Nodetectable Lnss No detectable Loss No detectable Loss No detectable Loss <br /> Criteria: <br /> Test Result: ® Pass 0 Fail I M Pass ❑Fail 0 Pass ❑Fail O Pass 0 Fail <br /> Comments (include information on repairs made prior to testing, and recommendedfollow-upjor failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.