Laserfiche WebLink
r . 7 • <br /> Remediation Piping Bid Request <br /> ARCO Station No. 6100 <br /> 25775 South Patterson Pass Road <br /> Tracy, California <br /> INTRODUCTION <br /> Atlantic Richfield Company(ARCO) is requesting bids for the installation of remediation piping <br /> to be completed during the present upgrade construction at ARCO station #6100. Delta <br /> Environmental Consultants, Inc. (Delta) is coordinating this work for ARCO. The contractor <br /> will perform all activities associated with the following scope of work and will work directly for <br /> ARCO. Delta will be responsible for soil sampling and provide oversight of construction <br /> activities related to environmental work. <br /> SCOPE OF WORK <br /> Contractor shall fiunish all necessary labor, material, equipment, permits, and inspections to <br /> perform the following work at the above location. All work is to be performed in accordance <br /> with the scope of work, site plan, and all applicable sections of ARCO specifications. <br /> General Conditions <br /> A. The Contractor will be trenching and installing PVC piping to existing monitoring wells <br /> and vapor wells for the purpose of later use for site remediation. The location of the <br /> wells and termination points are presented on Figure 1. Trenching details and vault <br /> details are presented on Figures 2 and 3. In general, the piping consists of 1) one 2-inch <br /> diameter schedule 40 PVC pipe with standard fittings for all directional changes required <br /> from the well to the termination point which will used for vapor extraction (this piping <br /> shall be installed to minim-dze any dips and with a slight slope back to the well), 2) one <br /> 2-inch diameter PVC line that will have electrical type sweeps at all directional change <br /> locations and will be used in the future as a conduit for air or electrical lines (these lines <br /> will be equipped with a pull string), and 3) one 1 inch diameter schedule 40 PVC pipe to <br /> be used for the discharge of water from the selected wells. Piping 1) and 3) will require a <br /> pressure test as noted on Figure. 2. A portion of this piping will be installed in the right- <br /> of-way area for Patterson Pass Road. ARCO will obtain the required encroachment <br /> permit from San Joaquin County. <br /> B. The nominal depth of the trenching will be 36 inches. The width of the trench will vary <br /> depending on the number of pipes to be bundled in the same trench as denoted on <br /> Figures 2 and 3. The trench will have an approximate 3 inch sand layer below the piping <br /> and an additional 3 inches of sand above the piping. Locator tape shall be placed in the <br /> trench. The remainder of the trench is to be filled with pea gravel allowing for the <br /> installation of 4 inches of asphalt to match surrounding grade. In those areas such as the <br /> pump islands and tank pit the ARCO construction requirements will be followed. <br />