My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WETMORE
>
210
>
2800 - Aboveground Petroleum Storage Program
>
PR0544025
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2019 4:20:12 PM
Creation date
7/11/2019 4:48:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0544025
PE
2832
FACILITY_ID
FA0005481
FACILITY_NAME
MANTECA CORP YARD
STREET_NUMBER
210
Direction
E
STREET_NAME
WETMORE
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21938313
CURRENT_STATUS
01
SITE_LOCATION
210 E WETMORE ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
25 October 2019 AdvancedGeo <br /> AGE Project No. 99-0637 F n v i ro n m e n t a l <br /> Page 12 of 19 <br /> 4.11. QUALIFIED OIL-FILLED OPERATIONAL EQUIPMENT - 40 CFR 112.7(k) <br /> There are no oil-filled operational equipment utilized at the facility, therefor this section <br /> does not apply. <br /> 5.0. DISCHARGE PREVENTION — SPCC PROVISIONS FOR THE FACILITY <br /> The following measures are implemented to prevent oil discharges during the handling, <br /> use or transfer of oil products at the Facility. Oil-handling employees have received <br /> training in the proper implementation of these measures. <br /> 5.1. FACILITY DRAINAGE - 40 CFR 112.8(b) <br /> ASTs at the Facility are constructed of double-wall construction. Any potential discharge <br /> from ASTs will be restrained by secondary containment structures or building walls. <br /> Discharges occurring during unloading operations will be restrained by spill kit equipment <br /> and absorbents until cleanup can occur. In the event of drainage events (may not be <br /> applicable), the form included in Appendix G of this Plan should be utilized to record the <br /> event. Records are maintained at the Facility for at least three years. <br /> 5.2. BULK STORAGE CONTAINERS - 40 CFR 112.8 (c) <br /> Table 8 summarizes the construction, volume, and content of bulk storage containers at <br /> the Facility. <br /> 5.2.1. Construction - 40 CFR 112.8 (c)(1) <br /> All ASTs used at this Facility are constructed of steel, in accordance with industry <br /> specifications as described above. The design and construction of all bulk storage <br /> containers are compatible with the characteristics of the oil product they contain, and with <br /> temperature and pressure conditions. There is no piping between fixed ASTs. <br /> 5.2.2. Secondary Containment - 40 CFR 112.8 (c)(2) <br /> The ASTs on-site are manufacturer constructed, double wall tanks and have internal <br /> secondary containment sufficient to contain 110% of the volume all contents. Each large <br /> generator has secondary containment pans at each setup (sufficient for fuel and motor <br /> oil). <br /> The 55-gallon drums are placed on spill pallets. Each spill pallet provides a 110% capacity <br /> in the event of a drum breach. <br />
The URL can be used to link to this page
Your browser does not support the video tag.