31 January 2002 <br /> AGE-NC Project No 95-0128 <br /> Page 4 of 8 <br /> The pump test consisted of extracting ground water from well EW-1 at a rate of 5 GPM utilizing a <br /> 4-inch diameter submersible Grundfos Redi-flo pump The pumping rate was determined by <br /> measuring the time required to fill a 5-gallon bucket-from.the pump discharge hose <br />' Thep pum test utilized 7/s-inch diameter, model 3001 Solinst Levelogger pressure transducers that <br /> were deployed in wells VW-3,VW-4 and VW-1 Each pi essure ti ansducei was preprograrnmed prior <br />' to the pumping test to log water levels at one-minute intervals However, no data was recorded from <br /> within vapoi well VW-1, due to an unanticipated and excessive drawdown of the water level in vapor <br /> well VW-1 Copies of pressure transducer water level data logged are in Appendices C <br />' The depth to ground water was also manually measured with a Solinst water meter in exti action well <br /> EW-1 and observation wells EW-2, MW-3, MW-4, MW-5, and MW-6 and vapor well VW-1 to <br />' VW-4 (Appendix D) Semi-logarithmic plots of draw-down versus time for observation wells are in <br /> Appendix E <br />' After 720 minutes of constant I ate pumping (5 GPM), the maximum ground water dr awn-down in f <br /> extraction well EW-1 was observed to be 8 4 feet Maximum draw-down in well VW-I (located equi- <br /> • gradient 5 feet toward the west) was 1 2 feet Draw-down in well EW-2 (located approximately <br /> down-gradient 15 feet toward the east) was 0 65 feet, draw-down in well VW-2 (located equi- <br /> giadient 22 feet towards the northeast) was 0 89 feet, draw-down In well VW-3 (located down- <br /> gradient 25 feet towards the east)was 0 8 feet,draw-down in well VW-4(located up-gradient 30 feet <br /> towards the west) was 0 5 feet, drawdown was observed in well MW-3 (located equi-gradient <br /> appy oximately 25 feet towards the northwest) at 0 41 feet, di aw-down in well MW-5(located down- <br /> gradient 60 feet towards the east) was 0 23 feet and was observed in well .'LViW-4 (located down- <br /> gradient approximately 70 feet towards the northeast) at 0 23 feet (Appendix D) Results of the <br /> aquifer ground water exti action test are summarized in Table 1 <br /> 1 An Inflection of the trend of the drawdown vs time plots at approximately 250 minutes suggests <br /> initiation of tui bulent flow into the extraction well with loss of well efficiency Steady state conditions <br />' may not have been achieved at the pumping i ate <br /> The maximum ground water di aw-down in observation wells versus the distance of each well from <br /> the extraction point was graphed on semi-logarithmic paper, utilizing the Distance-Drawdown <br /> Method, genes al values for the tiansmissivity, storati-v7ty and hydraulic conductivity of the aquifer, <br /> R were determined (Appendix F) <br /> Utilizing the data collected and plotted, atransrmssivity value of 380 ft'/day or 2,840 gallon/day/feet, <br /> a storativity value of 0 043, a hydi aulic conductivity value of 94 feet/day or 0 033 cm/s was <br /> calculated A calculation of the plume capture zone is included in Appendix G <br /> 4di anced GCOE11V ironmental Inc <br />