• sensor cord Into position Remove the indicator box cover Attach the indicator box to the PE <br /> mounting plates provided on the tank with the 2 ea 010 S S self-tapping screws Attach the sensor <br /> cable to the control box with small strain relief and connect wires per label in the box Connect unit to <br /> 110 VAC per label in the box using strain relief provided or other acceptable methods and test the <br /> unit The indicator box will show a green light when power is on and the sensor is not detecting a <br /> liquid The light Is a push to test light allowing the operator to test for power outage or malfunction If <br /> the green light goes out there are two posibildies The green light does not come on when the button <br /> is pushed This would indicate a lack of power to the unit or the light bulb is burned out If the green <br /> light comes on when pushed, then a possible leak condition is indicated <br /> 410 FLANGE ADAPTERS <br /> 4101 Standard flange adapters are constructed from PVC or CPVC and may be purchased for solvent <br /> weld socket fittings or threaded fittings Flange adapters for threaded fittings are provided with loose <br /> male adapter to allow the customer to adjust adapter length and flange position to match the piping <br /> at the Installation Refer to Figure 410 for an Illustration of a flange adapter <br /> 4102 When installing the flange adapter in a solvent weld socket fitting,cut the flange adapter to desired <br /> length and solvent weld the flange adapter vnth the proper solvent cement in the desired position in a <br /> previously installed fitting If the flange adapter Is to be used In a threaded fitting,install the male <br /> adapter into the fitting with Teflon®pipe sealant, cut the flange adapter to the desired length,and <br /> solvent weld the flange adapter to the male adapter in the desired position with the proper solvent <br /> cement <br /> 150# PVC RANGE <br /> O O <br /> 7 I <br /> 1 I O O <br /> I i <br /> 0 <br /> MALE AWTER (FOR TKREACEE] FITTINGS) <br /> Figure 4 10 <br /> 5. TANK ACCESSORIES <br /> 51 LATERAL RESTRAINT SYSTEM(FLAT BOTTOM TANKS) <br /> 51 1 The lateral restraint system is designed for tank position restraint on a concrete pad inside of an <br /> enclosed building It Is not designed for wind or seismic restraint capabilities. Using the <br /> assembly drawing and table shown in Figure 51,verify that all parts are present <br /> 512 Locate the tank on the concrete pad as desired The pact required for the restraint system must be <br /> 15-314" larger in diameter than the tank diameter for proper application of 112"adhesive anchor bolts <br /> 0 (assumes 6-3/9"edge distance required) Layout the bands around the tank(alternate long bands <br /> 17 <br />