My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EMBARCADERO
>
6649
>
2300 - Underground Storage Tank Program
>
PR0231098
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2020 4:45:55 PM
Creation date
7/24/2019 9:18:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231098
PE
2361
FACILITY_ID
FA0003830
FACILITY_NAME
VILLAGE WEST MARINA
STREET_NUMBER
6649
STREET_NAME
EMBARCADERO
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
09815006
CURRENT_STATUS
01
SITE_LOCATION
6649 EMBARCADERO DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
388
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />CONTINUATION FORM <br />Page: 4 of 5 <br />OFFICIAL INSPECTION REPORT <br />Date: 03/28/14 <br />Facility Address: 6649 Embarcadero Dr., Stockton <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />204. (continued) <br />L1 8/9/13 setup data warning <br />C2 8/9/13 setup data warning <br />L1 9/4/13 sensor out alarm <br />L1 (diesel STP) 9/4/13 fuel alarm <br />L3 (piping sump) 9/4/13 sensor out alarm <br />L3 (piping sump) 9/4/13 fuel alarm <br />C2 (diesel annular) 9/4/13 fuel alarm <br />L2 (premium STP) 9/10/13 sensor out alarm <br />L2 (premium STP) 9/10/13 fuel alarm <br />C1 (premium annular) 9/10/13 sensor out alarm <br />C1 (premium annular) 9/10/13 short alarm <br />C2 (diesel annular) 9/10/13 sensor out alarm <br />The monthly inspection report noted that the annular sensor had had repeated alarms and that the C1, <br />C2, and L2 alarms were due to troubleshooting the C1 sensor. No dates were listed. The attached work <br />order was for September 10, 2013 and noted C1, C2, and L2 alarms. During the monthly inspection, the <br />designated operator shall review the alarm history for the previous month, check that each alarm was <br />documented and responded to appropriately, and attach a copy of the alarm history with documentation <br />taken in response to any alarms to the monthly report. Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. REPEAT <br />VIOLATION <br />302 & 308. The premium STP sump was observed with the test boot not pulled back and the Schrader <br />valve pointed up. Any potential release from the primary containment into the secondary containment in <br />the premium piping does not flow into a collection sump. All secondary containment systems shall be <br />sloped so that all releases will flow to a collection sump located at the low point of the underground <br />piping. The test boot was adjusted by the technician at the time of inspection to ensure the valve is <br />downturned. REPEAT VIOLATION <br />305. The Bravo box float and chain in the UDC 2 and UDC 3 sumps failed to stop the flow of product at <br />the dispenser when tested. All monitoring equipment shall be maintained to activate an audible and <br />visual alarm or stop the flow of product at the dispenser when it detects a leak. The service technician <br />adjusted the floats and verified functionality. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AI_WY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Receiv <br />Title: <br />Stacy Rivera (209) 468-3440 <br />EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.