Laserfiche WebLink
i <br /> Ir <br /> Corrective Action Plan Page 11 <br /> Cutter/Western Lift Site <br /> GPE Project No. 102.3 <br /> December 12,2003 <br /> observations,''as recorded in the boring logs, and the purpose of the investigation will suggest <br /> which samples are appropriate for analysis. Selected soil samples from each boring will be <br /> submitted for analysis as follows: <br /> I <br /> • Total Petroleum Hydrocarbons as Gasoline (TPH-Gasoline) by EPA method 8015m, <br /> • Benzene,`Toluene, Ethylbenzene, and Total Xylenes (BTEX) by abbreviated EPA 8020, <br /> and <br /> The detection limits for those compounds are as follows: <br /> Compound TPH-G Benzene Toluene Ethyl Benzene Xylene <br /> Detection Limit 1.0 3.0 3.0 3.0 3.0 <br /> Units mg/kg µg/kg µg/k& µg/kg µg/kg <br /> I <br /> 5.4 Air Sample Analysis <br /> The air samples collected to monitor the vapor extraction remedial system will be analyzed on <br /> f by a state certified laboratory. <br /> • Total Petroleum Hydrocarbons as Gasoline (TPH-Gasoline) by EPA method 8015m, and <br /> r • Benzene, Toluene, Ethylbenzene, and Total Xylenes (BTEX) by abbreviated EPA 8020. <br /> The detection limits for those compounds are as follows:' <br /> Compound TPH-G Benzene+ Toluene Ethyl Benzene Xylene <br /> �+ Detection Limit 50 0.3 lil 0.3 i' 0.3' 0.3 <br /> rUnits µg/L µg2 !I: µg2 µg/L µg,/L <br /> i <br /> i <br /> I <br /> I <br /> I <br /> C; 2937 Veneman Ave.,#B240 Geo-Phase Environmental Inc. Phone(209)569-0293 <br /> Modesto,CA 95356 Fax(209)569-0295 <br /> it " <br />